My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6515 EVERGREEN WAY 2016-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
6515
>
6515 EVERGREEN WAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2017 11:05:04 AM
Creation date
2/9/2017 10:39:53 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6515
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 13, Z000 <br />� �- <br />'UBL/C f�!/ORKS <br />Barry Tetrick <br />8416 134`h Street NE <br />Arlington, WA 98223 <br />Subject: Owner: Tetrick <br />Address: 6�01 Rainier <br />Plan Check No.: B9�)12-O�Q <br />Dear Mr. Tetrick: <br />In response to your application for a construction permit, your plans have been examined and you are <br />advised that the issuance of a permit is being wi!hheld for the rea.�urs listed below. These comments <br />address building issues only. Additional revisions or additia�� may be required by other departments <br />(such as Utilities, Planning or Fire). All references refer to die 1997 Uniform Building Code, as <br />amended by the State of Wasilington and/or Washington State Energy Code 1997 Edition, unless <br />stated �:henvise. <br />In ordcr for thc processeng of your application to continue, it will be necessary to providc thc <br />Building Division with hvo cumplete new sets of druwings reflecting ti�e corrections requcsted. <br />Is it �our intention to use tlie same archi[ectural drawings (submitted 12-21-99)? If so, they must <br />be updated to agree with the Rib•Roo£structur3l drawings. If not, additional drawings will be <br />required including building elevations, office floor plans, exit locations, etc. See enclosed <br />check;is[. <br />2. The proposed upper level is required to be wheelchair accessible per UBC 1103. l.l . <br />3. The live load for which die upper level was designed to suppor[ (125 rsF) is required to be posted <br />throughout with durable metal signs located in conspicuous locntions. This requiremen[ should <br />be on the dra�vings. <br />Please prepare a response letter showing where each item in this letter is adaressed on the plan set. <br />Upon resubmittal of dte drawings, your application �vill be given priority and plan review will <br />recommencz. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure thnt the <br />proposed structu e will be constructed in compliance with ali adopted codes. <br />! ' <br />Sincerely, n� �.�,��-" <br />�� . <br />Steve i�liller <br />Associate Engineer <br />S:\S��IILLHR\Plan Check \'o. 69912-U.50.Joc <br />CITY OF EVERETT• 3200 Cedar Sireet • Everett.'NA 98201 •(425) 257-8800 • Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.