7307 EVERGREEN WAY 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
7307
>
7307 EVERGREEN WAY 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2018 10:27:27 AM
Creation date
2/9/2017 11:35:54 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7307
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5. PARTS ARL+A <br />5.1 Structural Description f <br />7 <br />The Parts Area building ia basically one story freme construction with a � <br />light frame szcond atocy covering the weat part. Th1s upper story is an � <br />extenoion of the second atory of the Service Entry building. The lower � <br />story coneiete of heavy timber roof decking aupported by glued laminated <br />beaas and freme bearing wulle. The beams are 3upported by three steel <br />, pipe coluame az�d frame bearing'walls. The beams were reportedly reused <br />from a previous building. <br />5.2 Structurttl Deficiencies <br />Tlie major structurul deficiency in thia area is the lack of sufficient <br />resietance to lsteral forcea in the north-south direction. An additional <br />de:iciency is the overlonding of the timber decking by the bearing walls <br />of the eecond story, where thie occurs. There are no signs of serious <br />deflecCion or failure of che tim6=r decking due to thSs overloading and <br />it doee not appear to be a aerious deficiency. <br />5.3 RECOMMENDATZONS <br />Provlde lateral resistance in the north-south direction by sheathing the <br />eaet aztd west walls of thie area with plywood, inetalling framing anchors <br />ai the top of the walls and providing additional bulting to the slab at <br />the bottom �f the walls. 'i'he modifications to the west wall of [his ar�a <br />were mentioned in paragraph 4.3 above. <br />Wc do not recoffinend that anything be done at present co reinforce the <br />timber decking for the loade of the upper story since it does not appear [o <br />be ha�-ing any aerious eFfects. In the event the condition becomas more <br />aerioue in the future, consideration should be given [o adding joist <br />b=tween the glued laminated beams [o support these loads. <br />� <br />k <br />� `� <br />;��U7 �cr ;. �'j. c��__: �,- . <br />