Laserfiche WebLink
SNOHOMISH <br />HEALTH DISTRICT <br />WWW.SNOHD.ORG <br />January 10, 2013 <br />Calvin Tam <br />10040 Sand Point Way NE <br />Seattle, WA 98125 <br />Subject: Proposed Fiesta Latina, 530 SW Everett Mall Way, Everett <br />_ ��V�I�LIVLSI�I <br />t a 'LU13 U <br />JAN 1 <br />Environmental Health Division <br />Dear Mr. Tam <br />Your plans have been reviewed with the Rules and Regulations of the State Board of Health, and with the policies <br />of the Snohomish Health District. With the addition of the following conditions, the plans are approved. <br />1. The conditional approval of the plans for Fiesta Latina was based upon the revised plans submitted <br />December 14, 2012. Any changes to the revised plans submitted December 14, 2012 without <br />preapproval from the Health District will void this approval. <br />2. Per the email from Robert Coronado received December 26, 2012, the previously proposed kitchen at <br />this establishment will not be installed at this time. Only the grocery is currently proposed. As such, <br />this conditional approval is for the grocery only. <br />3. An indirect waste drain (an air gap) is required for the walk-in refrigeration, refrigerated cases and any <br />equipment in which food or food contact equipment is placed. <br />4. No mop sink is included on the floor plan. A mop sink is required. The location of the mop sink must be <br />approved prior to installation. <br />5. Water heaters must be of sufficient size to provide hot water to all handwash sinks at the same time for <br />multiple consecutive hand washings. <br />6. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility must not <br />be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational inspection. This is <br />required so that proper testing of the 15-second time requirement for hot water availability can be completed. <br />7. All food service equipment, both new and used, must be listed by the National Sanitation Foundation (NSF) or <br />equivalent for its intended use. Used and new refrigeration must be capable of holding food at temperature of <br />41OF or below. <br />B. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed food service <br />establishment. Used equipment must be clean, in proper operating condition, and in good repair. Used <br />refrigeration must be capable of holding at a temperature of 41OF or below. <br />9. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and food <br />preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass -reinforced plastic or <br />equal is acceptable. A backsplash higher than 16 inches is required on the wall behind counter top equipment <br />taller than 16 inches. Wall protection behind mop sinks must cover the entire splash zone. Plastic coated <br />hardboard is not acceptable. <br />10. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be <br />surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw cuts and the <br />like in concrete floors in all areas, including customer seating areas, must be filled and sealed so as to <br />provide a smooth and cleanable surface. <br />11. The ceiling above the food preparation areas must be non -perforated, nonabsorbent, smooth and easily <br />cleanable. <br />3020 Rucker Avenue, Suite 104 a Everett, WA 98201-3900 ■ tel: 425.339.5250 ■ fax: 425.339.5254 <br />