Section I on Sheet 3, Section I on Sheet 4 and Section I oil Sheet S have also <br />been modified to show the slab insulation. <br />MECHANICAL No have been added to Sheet 3 indicating the requirements for <br />semi -heated spaces in accordance with Chapter 13 of the WSEC. (A gas fuueled <br />unit/system controlled by a thermostat with a uraxinan set point capacity of 45 <br />degrees has been noted. Therefore, wall insulation is not required by the <br />Exception under Section 1310.02) <br />Reference the BUILDING ENVFLOPF notes on Street I for the insulation and door <br />and ivindow callouts. <br />Since insulation is required on the addition, ive are raising the roof to align <br />with the roof at the main building. The plywood sheathing for both portions of <br />the building will be at the same level. The main roofslopes at 112:12, while the <br />storage roof will slope at 1:12. The slopes are indicated au the new Roo Plan <br />on new Sheet 4.1. <br />b. All spaces are considered be semi -heated, at minimum, per WSEC section 1301. <br />Pacific Response: <br />The new addition will be considered a semi -heated space. <br />2. The insulation, glazing and R-value at new doors and exterior envelope should be <br />shown on the drawings to meet the minimum requirements to comply with the 2009 <br />Washington State Energy Code. <br />Pacific Response: <br />Refer to Sheet 1 BUILDING ENVFt.oPE for the insulation, glazing and R-value at new <br />doors and exterior envelope. <br />Mechanical <br />1. A separate mechanical permit is required for new equipment and the distribution of air, <br />heat or cooling. <br />Pacific Response: <br />We have added MECHANICAL. NOTr:S onto Sheet 3 discussing the need for a separate <br />mechanical application and permit is required for all mechanical work. Additionally, <br />in our GFNaw, NoTEs an Sheet L I Note 28 discusses this as well. <br />OTHER MODIFICATIONS TO THE DRAWINGS <br />We have also made the following modifications to the drawings: <br />1. APPLICABLE CODESAND Rrrratr:Ncrs have been added to Sheet I (as indicated in our <br />meeting). <br />2. A typical note has been added in ;several places discussing the need for the <br />installation of a wood epoxy to be installed in the fire suppression cuts in the main <br />building's glue(!-laminnated roof beams. (Previous analysis indicates that the cuts dirt <br />not affect the glued-laminaled beans to support the code -required loads in shear.) <br />3. The removal and replacement of two additional interior doors are indicated on the <br />plans: the Restroon door (to hatch eldsting, the existing opening in the framing to <br />remain) and the door to Office #4 (existing slider modified to a pair of doors). <br />112'-OCurt N0 1SPI111•10-ILdoc II/10111 <br />