Laserfiche WebLink
B. Public Health, Safety, and General Welfare - Evaluation of the proposed <br />subdivision to determine whether the public health, safety, and general welfare has <br />been served. <br />Finding: The public health, safety, and general welfare are addressed through the <br />conditions of approval stated in this report. <br />Conclusion: The public health, safety, and general welfare have been served. <br />C. Comprehensive Plan - Evaluation of all elements of the Comprehensive Plan and its <br />consistency with the proposed short subdivision. <br />Finding: The Everett General Plan designates this area as 4.4, Mixed Use <br />Commercial/Multiple Family and 1.6, Multiple Family Residential. <br />Conclusion: The proposed short subdivision is consistent with the Everett General <br />Plan. <br />D. Existing Zoning - Evaluation of existing zoning and its compliance with the proposed <br />short subdivision and Section 18.24 of the Subdivision Code. <br />Finding: The site is comprised of two zoning designations, C-1 General Commercial <br />and R-3 Multiple Residential. The minimum lot area required in each of these zoning <br />areas is 5,000 square feet with a minimum lot width of 50 feet. The City's <br />Subdivision Code requires a minimum lot depth of 80 feet. <br />Proposed lot 1 is zoned C-1 and developed with a recreational bowling facility. <br />Currency there are 146 parking spaces provided for she bowling facility which <br />partially encroaches onto proposed lot 2 of the short plat. A redesign with new <br />parking areas for a total of 163 stalls will be provided entirely on lot 1 as part of this <br />proposal. This will remove all parking area encroachments on proposed lot 2. <br />The new parking area for lot 1 will be landscaped in accordance with the current <br />Zoning Code requirements. As shown on the proposed parking lot site plan a 10' <br />landscape strip will be provided along the 4th Avenue frontage and also the north and <br />west property lines landscaped to Type III Standards. A 5' strip will be provided <br />along the south property line also landscaped to Type III Standards. Landscaping <br />shall be provided for the interior parking lot area based upon the number of stalls <br />within the parking lot. The minimum requirement for 165 stalls is 5,705 square feet <br />of landscaping. <br />Proposed lot 2 is zoned C-1 and developed with an auto sales lot. This lot has <br />frontage on Evergreen Way which is an arterial street and will provide a landscape <br />strip a minimum of 10' wide planted to Type III Standards. <br />Proposed lot 3 is an undeveloped site that is split by C-1 General Commercial and R-3 <br />Multiple Residential Zoning. While this may create some challenges for development <br />of the site it does not violate any code requirements and is the applicant's preference. <br />The zoning boundary as shown on the preliminary short plat map is incorrect and <br />need not be shown on the final. <br />Conclusion: As proposed, each lot meets the minimum lot area, width and depth <br />requirements of the City s Zoning and Subdivision Codes. <br />