My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6011 FLEMING ST 2016-01-01 MF Import
>
Address Records
>
FLEMING ST
>
6011
>
6011 FLEMING ST 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/10/2017 5:11:35 PM
Creation date
2/10/2017 5:44:16 PM
Metadata
Fields
Template:
Address Document
Street Name
FLEMING ST
Street Number
6011
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />Gage 3 0l3 <br />�/Yathy/heilman/C1110-001 (6011 Fiemirg) <br />Ytotkr 11, 7011 <br />6. The stair detail on Sheet 8 shows a continuous run yet the plans show a landing at <br />mid-run; change detailto show proposed configuration. <br />7. The detail calls out "joists per plan", yet there is no freming pian for the landing; show <br />framing at landing. <br />8. The detail shows the handrail extending 1' — 0" beyond the top and bottom risers, but <br />the wall in the pian view ends at less than 1' — 0"; please clarify. <br />9. The upper floor plan sh�ws 36 inch min. cont. hand rail" where a guard per Section <br />R312 is required. Please provide a guard detail. <br />10. Provide guard detail for stairs. <br />11. Smoke alarm shall be centrally located in the corridor or area giving access to each <br />room used for sleeping. <br />12. At least on foundation vent shall be located within 3' — 0" of all corners. <br />13. Projections (roof overhang) extending into the 5 foot setback shall be 1-hour fire- <br />resistive construction on the underside of the projection. Provide detail of 1-hour fire- <br />resistive construction for the overhang on the entire north side of the proposed single <br />family residence (sfr). <br />14. The elevation views are labeled incorrectly. <br />15. The bollard in the garage shall be located such that it will prevent impact from <br />vehicles. <br />16. Provide (2) 6" x 12" screened openings in garage located (1) high, (1) low near the <br />water heater, for combustion air. <br />17. Specify U-value of all windows and doors. <br />18. The upper floor framing plan shows beams "UFB 2", ��UFB 5", and "UFB 6" in the entry <br />and the hali leading to the nook. Section 3 on Sheet A7 shows "UFB 2" incorrectly and <br />does not show (UFB 5 and I;FB 6". Please correct. <br />19. Specify hangers used at all locations that joist are hung on beams. <br />20. Provide gravity calculations for beams. Trace all loads to the foundation. <br />21. Tables 3-2, 3-3, 3-5, and 3-6 (labeled 3-5) are from the Washington State Ventilation <br />and Indoor Air Quality Code (VIAQ), which is no longer valid. Please update <br />ventilation requirements to the 2009 International Residential Code (IRC) per <br />Chapter 15 "Exhaust Systems". <br />22. Specify whole hou�e fan size and location per Section M1508. Note on drawings <br />whole house fan to be 1.0 SONE or less. <br />23. Attic ventilation calculations should be based on 1584 s.f. not 2280 s.f. Please revise <br />calculation (keep in mind that there are no ventilation openings allowed in the <br />overhang on the north side of the house). <br />24. Specify all componen[s in sections and details, do not reference "insulation per plans" <br />or "2 x studs per plans". <br />25. Insulatiori shall extend to the outside plane of the exterior walls. [nsulation baffles are <br />shown incorrectly. <br />ii <br />`: <br />s�kzthy/heilmaryClll0�001 (40I1 tleming) <br />
The URL can be used to link to this page
Your browser does not support the video tag.