My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2915 FULTON ST 2016-01-01 MF Import
>
Address Records
>
FULTON ST
>
2915
>
2915 FULTON ST 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2017 3:15:54 PM
Creation date
2/11/2017 3:15:36 PM
Metadata
Fields
Template:
Address Document
Street Name
FULTON ST
Street Number
2915
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
d. Prior to issuance of any pennits, landscapine nlans must be revicwed and approvcd by thc <br /> Planning Depanment per Section 35.100 of the Zoning Code. The landscaping plan must <br /> show location and dimensions of requircd vegetated swales, wetponds, detention ponds, <br /> rockeries and retaining �valls, and grading at 2 foot intervals. Imgation systems must be <br /> provided in all landscaped areas per Sectioi� 35.130 of the Zoning Code. A 2 year <br /> maintenance assurance device nnist be provided for the landscaping per Section 35.130B of <br /> thc Zoning Code. <br /> 17. Loading benhs must bc provided per Subsection 34.090 of Uic Zoning Code. <br /> i S. The site plan sho�.vs an electrical structure or vault in the public sidewalk on the ���est side of thc <br /> buildings. 1'his utility swcture must be designed and located so as to noi pose a hazard or <br /> obstruction to pedestrians. . <br /> 19. Access - O.K. as shown on the site plan reviewed. <br /> 20. Premise Identification - Premises sl�all be clearly identified by the correct address at the street entry. <br /> Buiidings shall be clearly identified so as to be visible and legible from dre access road. Individual <br /> apartments and suites, where applicable, shall bc clearly and legibly identified from the access road. <br /> 21. Fire Hvdrants - Locations as shown on the site plan are acceptable. <br /> 22. Fire Plow - Fire flo�v requirements for this structure are 1,500 gpm. <br /> 23. Fire Alarm Svstem - An approved automatic fire detection system shall be provided as required by <br /> City Ordinance No. 1902-92, Chapter 1G.76, of the Everett Municipal Code. <br /> Plans for such systcro shall be submitted to the Pire Marshal for review and approval prior to <br /> instalfation. Submittal shall include cut sheets of all equipment intended for use. Appropriate trip <br /> tests, wimessed by a Fire Department inspector, shall be performed, along with a certificate of <br /> completion, prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Standard 7'L. <br /> Fire alarm systems shall bu installed under permit of the City of Everett Building Department. <br /> Electrical inspections and approval aze required prior to calling for acceptance tests. Call (425) 257- <br /> 5310 for permit information. <br /> 24. Fire Suapression (Sprinklerl Svstem - An approved automatic suppression system shall be pro�•ided <br /> as required by Ciry Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. <br /> Plans for any such systcro shall be submitted to Aie Building Department and tlie Everett Fire <br /> Department Cor cxamination and approval. Such plans shall include plans for the underground mains <br /> 5� <br /> / ; � <br />
The URL can be used to link to this page
Your browser does not support the video tag.