13. Fire lanes shall be provided as required in Everett Municipal Code 46.44. Fire lanes shall be identified <br /> by red curbs with white stenciling stating "NO PARKING - FIRE LANE" and vertical signs stating "NO <br /> PARKING - FIRE LANE- TOW AWAY ZONE." Localion shall be approved by the Fire Ma�shal. <br /> 14. Premise Identification - Premises shall be clearly idenlified by the correct address at the street entry. <br /> Buildings shall be clearly identified so as to be visible and legible from the access road. Individual <br /> apartments and suites, where applicable, shall be clearly and legibly identified from the access road. <br /> 15. A fire hydrant is required within 200 driving feet, but not closer than 50 feet, of every structure. Location i <br /> of the hydrant(s) shall be approved by the Fire Marshal. 1 <br /> i <br /> 16. PREMISE IDENTIFICATION AND ALL REQUIRED FIRE DEPARTMENT ACCESS ROADS AND FIRE � <br /> HYDRANTS SHALL BE IN SERVICE PRIOR TO COMMENCEMENT OF CONSTRUCTION. <br /> 17. Based upon 12,015 square feet of Type V-1 Hr., sprinklered construction, the fire flow requirement is <br /> 1,500 gpm. I <br /> 18. Fire Alarm Svstem -An approved automatic fire detection system shall be provided as required by City <br /> Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Co�e. <br /> Plans for such system shall be submitted to the Fire Marshal for review and approval prior to installation. <br /> Submittal shall inciude cut sheets of all equipment inlended for use. Appropriate trip tests, witnessed by <br /> a Fire Department inspector, shall be performed, along with a certificate of completion, prior to final <br /> acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Slandard 7�. <br /> Fire alarm systems shall be installed under permit of the City of Everett Building Department. Electrical <br /> inspections and approval are required prior to calling for acceptance tests. Call (425) 257-8810 for <br /> permit information. <br /> 19. Fire Suppression (Sprinkler) Svstem -An approved automatic suppression system shall be provided as <br /> required by City Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. The system <br /> must include a mechanical water gong bell. <br /> Plans for any such system shall be submitted io ihe Building Department for examination and approval. <br /> Such plans shall include plans for the underground mains that will supply the sprinkler system. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 for <br /> private fire mains. All such tesls shall be witnessed by a Fire Department inspector. Call (425) 257- <br /> 8123 to make an appointment for inspection. <br /> Contractors' materials and test certificates shall be sub�nitted to the Everett Fire Department prior to <br /> issuance of any Certificales of Occupancy. <br /> Call (425) 257-8123 for more informalion. <br /> 20. Building setbacks must be a minimum of 10 feet front (east property line), 10 feet street side yard (soulh <br /> properly line), 0 feet interior side setback (north property line) and 0 feei rear yard (west property iine). <br /> The applicant has sought a modification from the code requirement which limits the encroachment of <br /> eaves to eigl�teen inches within a required setback. The applicant is proposing for eaves to extend two <br /> feet into ihe e2st, north an�i soulh facades, and variably up to three and a half feet on the south property <br /> � <br />