My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1000 SE EVERETT MALL WAY BASE FILE 2018-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
1000
>
BASE FILE
>
1000 SE EVERETT MALL WAY BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2019 8:19:18 AM
Creation date
2/13/2017 6:55:29 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1000
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Check 112� <br /> Larry Callahan <br /> August 9, 19II5 <br /> Page Three <br /> c. Placement of structural fill belo�•� the `loor• slab �•iill occur below <br /> the three-story portion and should require coinpaction tests. A report <br /> of satisfactory placement of fill , acceptable to you, should be sub- <br /> mitted. Section 2903(a; <br /> d. The soils rEport recomnends that all foundation bearing strata should <br /> be inspected by the soils engineer prior to placement of foundations. <br /> e. The perimet?r foundation drainage system, sho�an on Sheet A-9, should <br /> be detailed. <br /> f. The report recommencis a 2" sand layer, over the moisture barrier, below <br /> the slab-on-grade. <br /> g. The report repeatedly emphasizes that site soils are sensitive to over- <br /> wettin9 and that gradin9 during wet �aeather, or wet �aeatl�er nccuring <br /> after 9rading and prior to placement of slab and pavements, could <br /> result in areas requiring excavation and regrading. This should be <br /> carefully monitored by the soils engineer during construction. <br /> h. Because of this, you may wish to request laboratory tests determinin9 <br /> optimum moisture content of the site soils to insure that proper criteria <br /> is established. Section 2904(b) � <br /> 3. Foundations and retaining walls: <br /> a. I assume that the retaining walls betweeen grids J and L, 3.5 and <br /> 6, are to be reinforced per the retaining wall schedule on Sheet 5-1. <br /> Further details should be provided. 61any of the walls span horizontally <br /> to cross walls rather than vertically. Horizontal reinforcing at the ' <br /> exposed face is required under Lhat condition. Section 2303(b) <br /> b. The walls shown on F/S-1 also have the problem of spanning horizontally , <br /> in some locations, such as at C.6 and 2.7. <br /> c, Referring to Detail 1/5-2, the pier dimension parallel to grid L should <br /> be provided. Three #3 ties should be provided around anchor bolts within <br /> 5" of the top of the column. Section 2607(k)3.D. Based on the base <br /> plate and column dimensions given, the anchor bolts cannot be placed <br /> outside the column flanges as shown and still be within the ties, Yihile <br /> maintaining lZ' concrete cover over the ties as required in Section <br /> 2607(h). ; <br /> d. Three �3 or two �4 ties should also be provided in the top 5" around � <br /> the anchor bolts in �etails G/5-1, 2/S-7 and A/S-S. � <br />
The URL can be used to link to this page
Your browser does not support the video tag.