My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1402 SE EVERETT MALL WAY EXPRESS JAPAN 2018-01-02 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
1402
>
EXPRESS JAPAN
>
1402 SE EVERETT MALL WAY EXPRESS JAPAN 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2022 4:59:36 PM
Creation date
2/13/2017 7:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1402
Tenant Name
EXPRESS JAPAN
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
220e2 L-ORAIN ROAD <br />P4-10NE 26 - U )3 - 9554 <br />September 30, 2013 <br />Ms. Haley <br />Plans Examiner <br />Everett Public Works <br />FAIRVIEW PARK. OHIO 44126 <br />FAX 440 - 76 - 6937 <br />RE: Express Japan, TI <br />1402 SE Everett Mall Way, Food Court #623 <br />Review Number: B1309-012, M-1309-022, K1309-003 <br />Dear Ms. Haley: <br />In review of the Plan Review Letter, dated September 27, 2013, for the above referenced project, <br />LS Architects would like to respond as follows: <br />"'I. Door shall be an Eliason LWP-3 which complies, see revised drawing A-1. <br />-'2. Details have been revised to be non-combustible construction and a three in baffle has been <br />ladled see sheet A-2. <br />3.One hour fire wrap has been added to revised drawings see sheet M- I & A-2. <br />'4. Elevation has been provided 1/A-2, the is provided as a nonabsorbent and noncombustible <br />material. <br />5. Hood extends 6" beyond the edge of the top horizontal surface of all appliances, see <br />dimensions on drawing A-1. <br />A. No cleanouts required, exhaust duct shall run straight up though roof. <br />7. Notes have been added to drawings. <br />a. Duct material and size was noted on M-I plan. <br />b. Notation has been added. <br />c. Grease duct is supported by hood collar and hood''/z" threaded rod to unistruct at all four <br />corners. <br />Suppression <br />I. Cut sheet of chemical agent is attached. <br />2. Specific nozzle layout and dimensions for the equipment has been provided on revised <br />drawing M-2. <br />If you have any questions and/or concerns, please contact me at 216-403-9654. <br />Sincerely, <br />LS Architects <br />Leon S. Sampat, Architect <br />
The URL can be used to link to this page
Your browser does not support the video tag.