Laserfiche WebLink
�� SNOHOMISH <br />HEALTH <br />DISTRICT <br />August2,2011 <br />Janet Or <br />106 168�" St. SW <br />Mill Creek, WA 98012 <br />Subjeck Tea Topia, 607 SE Everett Mall Way #7, Everett <br />EN;!!RONMENTAL HEALTH DIVISION <br />3020 Fluc�PrAvenue, Suile 104 <br />Everett, WA 98�01-3900 <br />425.339.5250 FAX:415.339.5254 <br />Deaf/Hard of Hearing: 425.339.5252 (TTY) <br />Dear Ms. Or: <br />Your plans have been reviewed vaith the Rules and Requlations of the State Board of Health, and with the policies <br />of the Snohomish Health District. With the addition of the following conditions, the plans are approved. <br />, changesdto the menuv Junet 22,P2011 fwithoutTpre�approval from the Hcalth nDi tr ct m2ay �wi I this <br />approval. <br />2. The Health District operating permit application process must be completed prior to opening for business. <br />This facility will be classified as a medium risk food establishment with 0 to 12 seats. <br />3. Based upon the HACCP received June 22, 2011 you will be cooking the tapioca pearls on the counter top <br />induction cooker and as noted in the email received July 27, 2011 you will be hot holding the tapioca pearis in <br />the Nemco counter top rethermalizer/warmer mode! #6055A. This is an acceptable method for holding the <br />tapioca pearls provided that all leftover tapioca is discarded. No changes to this process will be allowed <br />without preapproval from the Health District. <br />4. An indirect waste drain is required for the food preparation sink, three-compartment sink, and any equipment <br />in which food or food contact equipment is placed. <br />5. Water heaters must be of sufficient size to provide hot water to dishwasher andlor scullery sinks and at the <br />same time provide hot water to all handwash sinks. <br />6. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility must not <br />be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational inspection. This is <br />required so that proper tesling of the 15-second time requirement for hot water availability can be completed. <br />7. All food service equipment, both new and used, must be listed by the National Sanitation Foundation (NSF) or <br />equivalent for its intended use. Used and new refrigeration must be capable of holding potentially hazardous <br />food at 41 °F or below. <br />8. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed food service <br />establishment. Used equipment must be clean, in proper operating condition, and in good repair. Used <br />refrigeration must be capable of holding potentially hazardous foods at a temperature of 41°F or below. <br />9. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and food <br />preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass-reinforced plastic or <br />equal is acceptable. A backsplash higher than 16 inches is required on the wall behind counter top eqwpment <br />taller than 16 inches Wall protection behind mop sinks must cover the entire splash zone. Plastic coated <br />hardboard is not acceptable. <br />10. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be <br />surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw cuts and the <br />like in concrete floors in all areas, including customer seating areas, must be filled and sealed so as to <br />provide a smoolh and cleanable surface. <br />11. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and easily <br />cleanable. <br />12 hold9unitlhteaelamps mu�srt be provideddw'thrshatte proof bulbs. Provided with covers or shatterproof bulbs. Hot <br />13. Plumbing must meet stale and local codes. <br />14. The ventilation system shall be installed and operated to meet applicable building, mechanical, and fire <br />codes. <br />