PIIBL/C WfiF/14 L <br />December 7, 1993 <br />M.. Lyle Blank <br />P. O. Box 2266 <br />Everett, Washington 98203 <br />RE: <br />Owner: <br />Job Add <br />Plan Ch <br />Dear Mr. Blank: <br />i <br />i <br />In response to your application for a construction permit, your plans have been examinee an3 <br />you are advised that the issuance of a permit is being withheld for the reasons listed bi low. <br />These comments address building issues only, additional revisions or additions ma > >,e <br />required by other departments (such as Utilities, Planning or Fire). All references refer ) t,te <br />1991 Uniform Building Code, as amended by the State of Washington and/or Washi gton <br />State Energy Code 1991, 2nd Edition, unless stated otherwise. <br />Blank & Ehlers <br />1. The plans submitted are incomplete. The comments that follow are general in nati - and <br />may not be complete. <br />An additional plan review response may be required after receipt of completed pla• ), , <br />2. All buildings and additions or alterations to buildings over 4,000 square feet r+xiuire the <br />plans and specifications to be prepared by an architect currently licensed to practice in the <br />State of Washington. RCW 18.08. Please note that current law allows design/build <br />contractors to assume responsibility if the drawings are stamped by a structural engineer <br />licensed in the State of Washington. If you chose this option please submit a letter stating <br />your acceptance of responsibility and have your engineer stamp and sign -ach sheet of the <br />drawings. <br />3. Group B1/B2 occupancies over 6,000 square feet [12,000 square feet with area separation <br />walls] shall be equipped with an automatic fire suppression system (fire sprinklers) per <br />City Ordinance 1902-92. <br />4. Group R1 occupancies located within buildings over 6,000 square feet shall be equipped <br />with an automatic fire suppression system (fire sprinklers) per City Ordinance 1902-92. <br />5. Group B1/B2/RI occupancies over 3,000 square feet shall be equipped with an automatic <br />fire detection system (fire alarm system) per City Ordinance 1902-92. <br />6. Final partition layouts and details for shell office areas shall be submitted prior to <br />installation to verify compliance with occupancy, fire -resistive, structural and exit <br />requirements. <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (206) 259.8800 • Fax (206) 259-8882 <br />TO <br />