9300 W MALL DR 2018-01-01 MF Import
>
Address Records
>
W MALL DR
>
9300
>
9300 W MALL DR 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2019 11:22:28 AM
Creation date
2/17/2017 11:44:15 PM
Metadata
Fields
Template:
Address Document
Street Name
W MALL DR
Street Number
9300
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Miscellaneous: <br />Catch basin #1 should have a solid lid. <br />A section from the north side of the site to the suuth side <br />of the site passing through the middle of both wetlands, L•he <br />wetpond, and the inlet and outlet from ti.� wetland system <br />sliould be provided (section C as drawn in on sheet C-3). <br />The existing ground elevations, proposed elevations, th•� <br />normal high water elevations in the wetlands, inverts �f <br />pipes, etc., should be shown. The elevation of the outte: <br />pipe relative to the existing ground elevation shculd be <br />made very clear. If the proposed locatian of the outlet <br />pipe is downstream of the local high point controlling the <br />water elevation in the wetland, the pipe invert should be <br />set at the existing ground elevation. However, if the <br />controlling point is located downstream of the proposed pipe <br />inlet location, and will be eliminated by the construction <br />of the south entrance, the elevation of the pipe invert must <br />be set at the elevation of the downstream high point. <br />More spot elevations are needed along the south driveway/ <br />entrance. <br />The site plan and the grading/drainage plan are not <br />consistent with each other in terms of the swale location <br />and access to the wetpond at the northern end of the pond - <br />the grading plan does not show a wetpond access or a swale. <br />A plan for restoration of any areas that will be disturbed <br />by the construction of stormwater facilities (e.g. swales, <br />wetpond, storm drains, etc.) will be required to be approved <br />by the Planning Dapartment prior to the disturbance. <br />A specially designated area will be required for washing of <br />cars by tenants of the complex. The area must be hydro- <br />logically isolated from the rest of the site, be covered, <br />and washwater from the area must drain to the sanitary sewer <br />after being routed through a baffle-type oil/water separator <br />designed to City standards. Signs must be posted on the <br />site limiting car washing to the designated area only. The <br />tenant lease or rental agreement must contain a clause <br />prohibiting car washing on the site outside of the specially <br />designated area. A covenant must be recorded and signed by <br />the owner stating that such a clause will be written into <br />the tenant leases and/or rental agreement.s. in addition, a <br />note stating that car washing is only permissible in the <br />designated area must be included on the storm drainage <br />plans. <br />As an alternative to the specially designated car washing <br />area, hose bibs can be eliminated from the site or tenant <br />access to them prevented. If this option is exercised, the <br />tenant lease or rental agreement must contain a clause <br />