Laserfiche WebLink
improvements shail be compleled, approvetl and warranted before the Uccupancy Permit is <br /> issued/final approval is granted. •� <br /> 2. A Traffic Mitiaatipn Fee of�900 00 (one new PM peak hour trip) shall be paid prior to the <br /> issuan-'" ce of any building permits for tl�is proposal. <br /> 3. Parking must be per City Zoning Code and City Desi�n and Construction Standards for <br /> Development. <br /> 4. Parking should be provided at a ratio of 3 spaces plus 2 per service b;;y (each spac� °� a <br /> service bay counts as a parking space). Parkino of vehicles related tc the automotive repa�; <br /> operation should occur off of the public riaht-of-way. <br /> 5. Any grading/fill on this sile shall be done so as to not impact the surrounding properties. <br /> 6. This project must comply with the current City of Everett Building Code and Sprinkler <br /> Ordinance. A building permit is required for construction. <br /> 7. Lack of r.omment on ihe plans submiited with the application does not constitute approval of <br /> these plans. <br /> 8. City streets and alleys are to be kept clear of dirt and debris at all times during consVcc:ior. <br /> Dust suppression and sireet cteaning must occur as directed by the Public Works Insper,tor. <br /> 9. Temporary erosion control measures for construction activity must be operationai prior to <br /> commencement of any clearing or earihwork. <br /> 10. Source controi measures will be required, in accordance with City standards, to prevent <br /> pollution of stormwater from the existing and proposed activities on the site. <br /> �1. All chemicals or products of a hazardous or toxic nature that may be used or stored on the site <br /> must be stored under cover and isolated from the storm drainage system. <br /> ��f vehicles or equipment will be washed and/or steam cleaned on this site_a designat2d ;�a: .` <br /> � area must be provided for these activitles. The area must be covered, paved with Portlano <br /> cement concrete, hydrologically_is.olated from the storm draina e s ste _ nd_must drain to the_ <br /> �_Y_m.�__ -- <br /> sanitary sewer through a,baffle_tyRe oil/water separator. A dischar�e authpii ation from the <br /> Ci 's InduslnaTPreEreatment Pro�ra_'m m�y b_@_re�uir�d For t��pr]Ilection to the sanitary — <br /> h' -- <br /> sewer. _WastewaEer from v✓ashing operations ma�Lnot be discharged to the storm system. <br /> 13.A discharge authorization (rom the City's Industrial Pretreatment Program may be requireo ic: <br /> connecfio�s to the sanitery sewer. <br /> -. ��cc�,s - O.K. as shown on the site plan reviewed. <br /> .� <br /> ' 15.4Cnox Box for qate - When access to or within a structure cr an area is unduly difficult beczuse <br /> '��of secured openings or where immediate access is necessary for life saving or fire-fighting <br /> purposes, the Fire Department may recommend or require a key box to be installed in an <br /> accessible location. A rapid entry system may also be desirable in order to avoid unnecessary <br /> damage while making enlry to any building during an emergency situation. <br /> Please call (425) 257-8123 for further information. <br /> 16. Premise Identificaiion - Premises shall be clear ' ed by ihe correct address at the sireet� <br /> e`_ n�Buildings shall b�'CfearT en ified so as to be visibte egib e r e access road-J <br /> '^dividual apartments and suites, where applicable, shall be clearly and legibly identified from <br /> '�� access road. Must be localed at Holly Drive (with arrow pointing tow�ard entry) and on gate. <br /> ' \ <br /> ������ <br /> — , xi,, -.�- <br /> � <br /> � <br />