My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10630 HOLLY DR 2016-01-01 MF Import
>
Address Records
>
HOLLY DR
>
10630
>
10630 HOLLY DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2017 11:24:01 AM
Creation date
2/18/2017 11:23:54 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
10630
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
17. Fire Hvdrants - Locations as shown on the site plan are acceptable. <br /> 18. Flammable Finishes & Soravinq - Provide a portablE fire extinguisher with a minimum U.L. <br /> rating of 4-A:40-B:C within 30 feet or 4-A:80-B:C wilhin 50 feet ofihe spray area. <br /> —".�1J,9%Fire Suopression lSprinkler) Svstem -An approved automa�ic suppression system shall be <br /> -� providc;d as required by City Ordinance No. 1902-92, Chapter 16.76, of the EVerett hlunicir�al <br /> C- .1,- The system must inciude a mechanical water gong tell. <br /> �lans for any such system shall be submitted to the Building Department for examina:lon and <br /> approval. Such plans shall include plans for the undergrounci mains that will supaly ihe <br /> sprinkler system. , <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standa;d <br /> 13. Underground pipinc� shail be hydrostatically tested and flushed as established in NFPA <br /> Standard 24 for private fire mains. All such tests shall be witnessed by a Fire Departinent <br /> inspector. Call (425) 257-8123 to rnake an appointment for inspection. <br /> Contractors' materials and test certificates shall be submitted to the Everett Fire Department <br /> �ror to issuance of any Certificates of Occupancy. <br /> A mecFunical water gong is not required. <br /> Cail (425) 257-8123 for more information. <br />� ' 9�1Fire Alarm Svstem (for�hell buildinq - must include suopression svstem activation notification <br /> �� and monitorina at a central station) -An approved automatic fire detecti�n system shall be <br /> provided as required by City Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal <br /> Code. <br /> ^'2ns for such system shall be submitted to the Fire Marshal for review and approva! prior to <br /> installation. Submittal shall include cut sheets af all equipment intended for use. Appropriate <br /> trip tests, witnessed by a Fire Depariment inspector, shall be performed, along with a certifiate <br /> of completion, prior to final accepiance of the system. <br /> Fire alarm systems shall be installed according to NFPA Standard 72. <br /> Fire alarm systems shall be install�d under permit of lhe City of Everett Building Department. <br /> Electrical inspeclions and approval are required prior to cailing tor acceptance tests. Call (425) <br /> 257-8910 for permit informalion. <br /> '. ;'�' `re afartn control panels (FACP) and sprinkler valves shatl be in heated rooms or clostts <br /> with standard man door access. Locations shall be approved by tiie Fire Marshal's Office. <br /> 22. A permit is required from the Fire Department for: <br /> Flammable or combustible liauids. To store, handle or use Class I liquids in excess of 5 gallons <br /> � G �::ilding or in excess of 10 gallons outside of a building. <br /> Flammahie or combustible liauids. To store, handle or use Class II or Class III-A liqu�ds in <br /> excess of 25 gallons in a building or in excess of 60 gallons outside a building, except for ;uel <br /> oil used in connection with oil-burnin� equipment. <br /> ,� � <br /> �"� �J ) <br /> - - -- �- - <br /> ` <br />