Laserfiche WebLink
MITIGATION REQUIRED EY EXTSTING CODES AND ORDINANCES <br />la. One additional fire hydrant is required within 200 driving feet <br />but not closer than 50 feet, of the proposed bu:.lding preferak�ly <br />at the corner of Hoyt and 43rd Street per Ordinance 473-80. <br />(SEPA Public Services and Utilities Policies) <br />lb. In accordance with Article 10.208(a) of tLe Uniform Fire Code, <br />and Subsection 36.180 of the Zoninq Code, a�proved numbers or <br />addresses sh� _1 be placed on all new and existing bui.ldings in <br />such a position as to be plai.nly visible and legible from �lie <br />street or road fronting the Property. The size, material, exact <br />location, and contrasting background must the review and approved <br />by the Public Works or Fire Department. <br />lc. Lased on the proposed 7,280 square feet of Type V-N constructioi*., <br />the fire flow reciuirement is 2,250 GPM <br />id. Portable Fire Protection is required. A portable fire <br />extinquisher with a minimum UL �ating of 2A must be provided <br />within 75 feet travel distance of all portions of each building <br />during construction and prior to occupancy. (SEPA Public Services <br />and Utilities Pr,licies) <br />2. Full standard }131f street improvements are required to 43rd <br />Street and Hoyt on the proposal's full frontage per City Design <br />Standards, includina but not limited to, curb, gutter, sidewalk, <br />street widening for a street width of 18 feet from centerline <br />per Ordinance 555-78 as amended. Also, full standard alley <br />inprovements are required on the proposal's full frontage per <br />City Design Standards. (SEPA Transportation Policies) <br />3. The proposal must comply with the City's craific mitigation <br />requirement. Assessed traffic impact £ees of $E,S00 must be paid <br />by applicant to the City's Traffic MitigaY.icn Fund prior to the <br />issuance of Building and Public Works permits per Interim Traffic <br />Mitigation Ordinance 1670-89. (SEPA Transportation Policies) <br />4a. Special charges for connection to the utilities system in <br />accordance with Ordinance 1171-85 are applicable. The actual <br />cost shali be computed by the building Department per tt�e <br />ordinance in effect at the time and accor.ding to the information <br />provided on the approved plans on th� date of permit issuance. <br />4b. On-site dFtention is required for this site. The site must be <br />qraded to dr.ain to the separate storm sewer on the 43rd and Hoyt <br />Streets intersection. (SEPA Public Services and Utilities <br />Polici4s) <br />5. F3rking must be per City Zoning Code and City Design and <br />Construction Standards. For the 7,380 sqi:are feet of inedical. <br />clinic proposed, a minimum o£ 37 parking stalls ar.e required. <br />(SEPA Transportation Policies) <br />2 <br />