My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2508 GRAND AVE 2016-01-01 MF Import
>
Address Records
>
GRAND AVE
>
2508
>
2508 GRAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2017 9:26:29 AM
Creation date
2/20/2017 7:27:08 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2508
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
191
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � � <br />4. Bedroom 6 appears to be smaller than the minimum size (in width) for a habitable <br />room. Habitable rooins shall have a Floor area of not less than 70 sq ft. Habitable <br />rooms shall not be less than 7 feet in any horizontc! dimension. <br />5. Snohomish County records show a total of 4 bedrooms and 2 bathrooms. The plans <br />submitted show 8 bedrooms and 3 bathrooms. The plans should show all new walls <br />that were added without permits. Use different symbols on the plan to show: existing <br />walls, new walls, and walls to be removed. Show dimensions of all rooms. <br />6. All plans shall be drawn to a standard architectural scale. Floor plans are '/a" = 1'-0" <br />scaie. Details and sections are drawn at a larger scale such as'/z" = 1'-0", 3/a" = 1'-0" <br />or larger. <br />7. Provide minimum 50 cfin exhaust fan in bathrooms and laundry room/area. Exhaust <br />fans shall be vent�d to the exterior. <br />8. Provide minimum 100 cfin exhaust fan in kitchen vented to the exterior. <br />9. The zone code restricts single family residences to one kitchen. Duplexes are allowed in <br />the zone the house is located in. A duplex requires one-hour fire-resistive construdion <br />between dwellings located in the same structure. Duplexes are also required to have a <br />living room, dining room and kitchen that meet the minimum room areas specified in <br />section R304 IRC. Please revise plans to reFlect your intended usc of the structure, <br />single family residence or duplex. <br />Please prepare a response letter showing where each item in this correction letter is <br />addressed on the plan set. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to e�sure <br />that the proposed structure will be constructed in compliance wilh ali adopted codes. <br />,ciifiLCrn.ir <br />��,�.�- <br />]eff Heilman <br />Development Technician <br />425-257-8976 <br />Email: jheilma_n aici.everelt.wa_us <br />4Ufnmmon�Ocn[alUHrilman1U207�032 R508 Grand A�cl.tloc <br />