My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2701 GRAND AVE 2018-01-02 MF Import
>
Address Records
>
GRAND AVE
>
2701
>
2701 GRAND AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2022 11:28:12 AM
Creation date
2/20/2017 7:49:37 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2701
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R E P O R T <br />FROM: Marian Payne, Housing Inspector /►(�► <br />DATE: October 22, 1991 1j <br />RE: 2701 Grand Avenue <br />The following report lists violations noted during the inspection as <br />referenced by the Uniform House Code. Not all the violations are listed, as <br />it was difficult to know where to begin since the list for those things which <br />are OK would be much shorter than the list for every single item that was in <br />violation of the Code. <br />1. The occupancy of the house has been converted without going <br />through the required permit process. <br />2. Electrical service has been altered, spliced together with the <br />fuse box and breaker box with wires hanging unprotected from the <br />service. <br />3. The kitchen is unsanitary; appliances scattered around but <br />plugged in for use. <br />4. There is plumbing which can siphon gray water back into potable <br />water. <br />5. Electrical wires and extension cords hanging and strewn around <br />the interior and exterior of the building. <br />6. No fire separation between rooms or floors. <br />7. Holes in walls, floors and ceilings. <br />8. No light in second story hall or staircase. <br />9. There is no emergency exiting for the basement apartment. <br />10. There is no protection from the elements for the exterior of the <br />building. <br />11. The roof is rotted. <br />12. The chimney is deteriorated. <br />13. All sleeping rooms shall have one window meeting the requirements <br />of the Uniform Building Code for emergency egress. <br />14. All habitable rooms shall be supplied with an approved heating <br />system that is capable of maintaining a temperature of 73 degree <br />F. at a point of 2 feet above the floor. <br />
The URL can be used to link to this page
Your browser does not support the video tag.