Laserfiche WebLink
.; <br />9 <br />> <br />�� <br />Beam Construction, Inc. <br />November 1, 1990 <br />Page two <br />I�uw� <br />6. Provide thermal break between dwelling and garage. NWEC. <br />everett <br />, <br />� i <br />I � <br />��', <br />, 7. Shower shalt be finished with a smooth, hard, nonabsorbent material <br />to a height of not less than 70 inches above drain inlet. Materials <br />:j other than structural elements shall be of a type which is not <br />., adversely affected by moisture. See Section 4712 UBC for other <br />' limitations. 510 UBC. <br />8 <br />0 <br />10 <br />Glazing subject to human impact and/or glazing in hazardous locations <br />as defined in Section 5406(d) UBC shall conform to the requirements <br />of Section 5406 af the Uniform Building Code. <br />Provide 5/8" Type 'X' GWB on all walls and ceiling in garage, wrap <br />columns and beams. <br />Garage door headers overstressed. Provide size species and grade �f <br />properly sized headers. <br />11. Provide concrete footing at post supporting beams in garage. <br />12. Typical wall section provided is not applicable io �`,:� sLiucture. <br />Provide wall sections indicating 2-story framc construction, and a <br />section, indicating below grade retaining wall with framing above <br />sections, shall indicate all members with sufficient detail to <br />indicate construction complies with City of Everett building <br />requirements and Northwest Energy Coda. <br />13. Provide detail of retaining wall at front porch next to driveway. <br />14. The slope of cut surfaces shall be no steeper than is safe for the <br />intended use and shall be no steeper than 2 horizontal to 1 vertical <br />unless the owner furnishes a soils engineering or an engineering <br />_ geology report, or both, stating that the site has been investigated <br />and giving an opinion that a cut at a steeper slope will be stable <br />and not create a hazard to pubiic or private property. <br />15 <br />16 <br />Indicate on plans how requirements of Section 3205(c) (ventilation) <br />are met. Indicate size (net clear area) of vents to be used. , <br />Plans do not indicate type of siding to be used. <br />17. All structural plywood, particleboard, and/or oriented strandboard <br />used in conditioned spaces shall be labeled exposure 1 or exterior <br />(phenol based) or less than .2 PPM for plywood, or Less than .3 PPM <br />for particle board (formaldehyde based). <br />18. Please take revised plans back to P.U.D. to get energy code <br />compliance stamp on both sets of drawings. Energy Plan Review No. <br />OS-0174. <br />