Laserfiche WebLink
wetponds, detention ponds, rockeries and retaining walls, and grading at 2 foot <br />intervals. Irrigation systems must be provided in all landscaped areas per Section <br />35.130 of the Zoning Code. A 2 year m�:ntenance assurance device must be <br />provided for the landscaping per Section 35.130B of the Zoning Code. <br />20. Outdoor parking areas shall be separated from streets and abutting properties in <br />accordance with the setback standards containcd in the Use-Standerds Table and shall be <br />Iandscaped in accordance witn the standards in Subsection 35.080. <br />21. The Unifortn Fire Code requ'ves that all new structures shall provide Firc Department <br />access roads to within 150 feet of all portions of the ground 800r. Fire Department access <br />roads (Fire Lanes) stull Qrovide a minimum of 20 feet i,� width of unobstructed, all-season <br />driving surface with a mmimum clear height of 13'6". F'ire Lanes will be posted and <br />maintained as required by the Fire Department. <br />22. Based upon 11,616square fcet of Type V-N, spriciklered constnictioq the fire E�w <br />requirement for the ofbce/warehouse is 1�500 GPM. Based upon 11,125 square feet of <br />Type V-N, sprinklered construction, the fire flow requirement for the shop and canopy is <br />l� GPM. <br />23. A fire hydrant is reyu'ved within 200 driving feet, but not closer than 50 feet, of every <br />suucture. M addihonal hydrant must be installcd. The location of the hydrant must be <br />approved by the Firo Marshal. <br />24. M approved sutomatic suppression system shall be provided ns required by City <br />Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. <br />Plans for any such system must be submitted to the Building Depaztment and the Everett <br />Fire Department for examination and approval. Such plans must include plans for the <br />underground mains that will supply the sprinkler system <br />Above ground sprinkler piping must be hydrostatically tested es estabGshed in NFPA <br />Standard 13. Undergound pipmg must be hydrostatically tested and flusfud as <br />established in NFPA Standard 24 for private 6re mains. All such tests must be witnessed <br />by a Fire Department inspector. Ca11259-8710 to make an appointment for inspection. <br />Contractors' materials and test cectiScates must be submitted to the Everett Fire <br />Department prior to issuance of any CertiScates of Occupancy. <br />Call 259-8720 for more infonnation. <br />25. The building must have a fire alartn system installed in accordance with Uniform Fire Code <br />Standards 10-2. <br />