My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6525 HARDESON RD BASE FILE 2016-01-01 MF Import
>
Address Records
>
HARDESON RD
>
6525
>
BASE FILE
>
6525 HARDESON RD BASE FILE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2017 11:35:32 AM
Creation date
2/20/2017 10:57:56 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
6525
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
308
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Contractors' materials and test certificates must be submitted ro the Everett Fire <br />Department prior to issuance of any Certificates of Occupancy. <br />Call 257-8123 for more information. <br />39. Fire Al�rm CySt�m An approved automatic fire detection system shall be provided as <br />required by City Ordinance No. 1902-92, Chapter 16.76 of the Everett Mumcipal <br />Code. <br />Plans for such system shall be submitted to the Pire Marshal for review and approval <br />prior to installation. Submittal shall include cut sheets of all equipment intended for <br />use. Appropriate trip tests, witnessed by a Fire Department inspector, shall be <br />performed, along with a certificate of completion, pnor to final acceptance of the <br />system. <br />Fire alarm systems shall be installed according to NFPA Standard 72. <br />Fire alarm systems shall be installed under pertnit of the Ciry of Everett Building <br />Department. Electrical inspections and approval are required prior to calling for <br />acceptance tests. Calt 257-8810 for permu information. <br />40. A ponable fire extinguisher with a minimum UL rating of 2A:10-B:C must be provided <br />within 75 feet travel distance on each floor of all portions of each building during <br />construction. <br />41. Fire lanes must be provided as required in Everett Municipal Code 46.44. Fire lanes <br />must be identified by red curbs with white stenciling stating "NO PARKING - FIRE <br />LANE" and vertical signs stating "NO PARKING - FIRE LANE - TOW AWAY <br />ZONE." Location must be apprnved by the Fire Marshal. <br />42. The premises must be clearly identified by address at the street entry. The building <br />must be clearly identified so as to be visible and legible from the access road. <br />43. PREMISE IDENTIFICATION AND ALL REQUIRED FIRE DEPARTMENT <br />ACCESS ROADS AND FIRE HYDRANTS SHALL BE IN SERVICE PRIOR TO <br />COMMENCEMENT OF CONSTRUCTION. <br />44. Hiy;h Piled Storaee Buildings containing high-piled combustible storage shall be in <br />accordance with Article 81 of the 1994 Unifom� Fire Code and Articles 81-1 and 81-2 <br />of the 1994 Uniform Fire Code Standards. A Fire Department permit is required for <br />high-piled storage. <br />45. Hazardo�s Materials In order to expedite plan review, a hazardous materials invenrory <br />shall be provided as a part of the submittal for building permit. The storage, handling <br />and use of hazardous materials shall be in compliance wuh Anicle 80 of the Uniform <br />Fire Code, 1994 EJition. <br />The storage, handling and use of flammable or combustible liquids shall comply with <br />Artide 79 of the Uniform Fire Code, 1994 Edition. <br />Please call 257-8123 for further information. <br />46. Although the projected employment for King Extrusions is below the Commute Trip <br />Reduction (CTR) threshold of 100 employees, the Ciry can assist in helping to define <br />I�l <br />