My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7425 HARDESON RD BASE FILE 2016-01-01 MF Import
>
Address Records
>
HARDESON RD
>
7425
>
BASE FILE
>
7425 HARDESON RD BASE FILE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2017 11:03:58 PM
Creation date
2/20/2017 11:52:59 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7425
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />� <br />� <br />� <br />� <br />� <br />��_l <br />� <br />I� <br />�� <br />�' <br />� <br />� <br />� <br />� <br />� <br />� <br />� <br />� <br />�� <br />GEOTECHNICAL ENGINEERING STUDY <br />Traa; and Associates <br />July 1£�, 2005 <br />E-11860 <br />Page 9 <br />Footinc� excavations should be observed by a representative of ECI, prior to placing <br />forms or rebar, to verify that soil conditions are as anticipated in this report. <br />Slab-on•Grade Floors <br />The slab-on-grade floors for tlie buildings and the bottom of the vault should be <br />supported on a minimum of 12 inches of structural fill. <br />The slab-on-grade floors should be provided with a capillary break consisting of a <br />minimum of 4 inclies of free-draining sand or gravel. In areas where slab moisture is <br />undesirable, a vapor barrier, such as a 6-mil plastic membrane, should be placed beneath <br />the slab. <br />Retaining Wal�s and Stormwater Control Vault <br />The proposed stormwater control vault retaining walis and other retaining walls should <br />be designed to resist tl�e lateral loads imposed by the retained soils and applicable <br />surcharge loads. <br />Walls that are designed to yield can be designed to resist the lateral earth pressures <br />imposed by an equivalent fluid with a unit weight of 35 pcf. If walls are to be restrained <br />at tl�e top from iree movement, tlie equivalent fluid weight should be increased to 50 pcf. <br />These values are based on horizontal backfill conditions. Surcharges due to backfill <br />slopes, hydrostatic pressures, traffic, structural loads, or other surcharge loads are <br />assumed to not act on the wall. If such surcharges are to apply, they should be added to <br />the above design lateral pressure. The passive pressure, allowable bearing capacity, and <br />iriction coefficient previously provided in tho Foundations section are applicable to the <br />retaining waA design. <br />To reduce tlie potential for hydrostatic pressures to build up behind site retaining walls, <br />including the stormwater control vault retaining walls, the walls should be backfilled with <br />a iree-draining material extending at least 18 inches behind the wall. The free draining <br />backfill should consist of eitlier pea gravel or washed rock. A rigid, 4-inch diameter, <br />scl�edule 40 PVC or SDR 35, perforated drain pipe should be placed at the base of the <br />wall and should be surrounded by a minimum of 1 cubic foot per lineal foot with 1-inch <br />washed rock. The drainpipe should be placed with the perforations in the down position, <br />The remainder of the backfill should consist of structural fill. <br />Garth Consullan�s, Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.