Laserfiche WebLink
' . <br /> roofline variation, established neighborhoods, building materials and maintenance, <br /> parking location, podestrian access, and designing for safety. The site must be <br /> ' developed per the proposed site plan, lighting plan, and building elevations, or <br /> additional nview will be required. <br /> Fire Departmeut Commenks i <br /> 22. Access - O.K. as shown on the site plan reviewed. <br /> 23. Premise Identification - Premises shall be clearly iden6fied by the correct address <br /> at the street entry, Buildings shall be clearly identified so as to be visible and <br /> legible from the access road. Individual apartments and suites, where applicable, <br /> shail be clearly and legibly identified from the access road. <br /> 24. Fire Hvdrants - I.ocations as shown on lhe site plan are acceptable. <br /> 25. Fire Flow - Fire flow requirements for this structure �re 1,500 gpm. <br /> 26. Portable Fire Protecdon - A portable fire extinguisher with a minimum U.L. � <br /> rating of 2-A:10-B:C shall be provided within 75 feet of travel on all floors of <br /> each building during construction and prior to occupancy. <br /> 27. Fire Alarm Svstem (All Buildinrts) - An approved automatic fire detection system <br /> shall be provided as required by Ciry Ordinance No. 1902-92, Chapter 16.76, of <br /> the Everett Municipal Code. <br /> Plans for such system shall be submitted to the Fin Marshal for review and <br /> approval prior to installation. Submival shall include cut sheets of all equipment <br /> intended for use. Appropriate trip tests, witnessed by a Fire Depaxtment <br /> inspector, shall be performed, along with a certificate of compledon, prior to final <br /> acceptance of the system. I <br /> Fire alarm systems shall be instailed according to NFPA Standard 72. I <br /> Fire alarm systems shall be installed under permit of the Ciry of Everett Building <br /> � Department. Electrical inspections and approval are icquired prior to calling for <br /> acceptance tests. Call (425) 257-8810 for permit information. <br /> 28. Fire Suppression (Sprinkler) Svstem (All BuildinQs) - An approved automatic <br /> suppression system shall be provided as required by City Ordinance No. 1902-92, <br /> Chapter 16.76, of the Everett Municipal Code. <br /> Plans for such system shall be submitted to the Building Department and the <br /> Everett Fire Department for examination and approval. Such plans shall include <br /> plans for the underground mains that will supply the sprinkler system. <br />