Laserfiche WebLink
4. If the ara e entrance is locked, access to an unlocked man door within the garage direcdy to the <br /> 9 9 <br /> public way should be provided. IBC section 1014.2 (2) <br /> � 5. Clear aisle width of minimum 36 inches should be shown on the drawings. IBC section 1017.2 <br /> �6. Where changes of elevation of less than 12 inches exist in the means of egress, sloped surfaces should <br /> be shown on the drawings. IBC section 1003.5 <br /> � 7. Tactile exit signs should be shown on the drawings adjacent to each door to the exit discharge. IBC <br /> sedion 1011.3 <br /> ✓'8. Exit discharge cannot reenter the building. IBC section 1027.1 <br /> Construction <br /> ✓ 1. Please indicate on the drawings that the minimum STC and IIC ratings have been met by existing <br /> construction or a combination of existing and new construdion to separate the residences above from <br /> this tenant space. IBC sedions 1207.2 and 1207.3 <br /> �. Hardware for new doors should be identified on the door schedule to not require tight grasping, <br /> pinching or twisting of the wrist to operate. IBC section 3008.9.1. <br /> Ao�essibflity <br /> 1. Please show the following dimensions in all toilet rooms: ICC A117.1-2003 Section 603 <br /> a. Toilet paper dispenser distance from toilet. <br /> b. Clear turnarounc' space (not impaired by fixtures) <br /> c. Fve foot clear space at toilet (between wall and sink) <br /> Energy <br /> 1. Steel stud walls should be shown with minimum R-13 plus R-7.5 continuous insulation at exterior walls, <br /> v o-walls adjacent to unheated or semi-heated spaces, such as the adjacent garege and adjacent <br /> unoccupied tenant space. WSEC table 13-1 <br /> These comments address building issues only. Revisions or additions may be required by other departments <br /> (Utilities, Public Works, or Planning). Code references cited include the 2009 Intemational Building Code <br /> (IBC), 2009 International Fire Code (IFC), the 2009 International Mechanical Code (IMC), the Uniform <br /> Plumbing Code (UPC), the 2009 Washington State Energy Code (WSEC), and the ICC/ANSI A117.1-2003 <br /> Accessible and Usable Buildings and Facilities. All codes referenced, as adopted by the City of Everett, should <br /> include current revisions by the State of Washington. Note that federal laws may be more restrictive. Please <br /> contact me with any questions at 425-257-8813. <br /> Si erely, __, <br /> ` <br /> g Haley, la;�s � aminer <br /> Cc. Steve Mill\eT;C' of Everelt <br /> I � <br />