My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1315 PACIFIC AVE 2018-01-01 MF Import
>
Address Records
>
PACIFIC AVE
>
1315
>
1315 PACIFIC AVE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2018 9:27:38 AM
Creation date
2/25/2017 5:38:58 AM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
1315
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
379
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� �` <br /> f. Where directed by the Fire Code OKcial, specific areas shail be designated and those areas are <br /> to be mnrkeu wilh diagonal striping across the width of the fire lane. Diagonal marking shall be <br /> used in conjunction with painled curbs and/or edge striping and shall run at an angie of 30 to 60 <br /> degrees from one side to the other. These diagonal lines shall be in red traific paint, parallel with <br /> each other, at least 6 inches in width and 24 inches apart. Lettering sha(I eppear as above. <br /> 21. Premises shall be clearly identified by the correct address at the street entry. Buildings shall be clearly <br /> identified so as to be visib and legible from the access road. Individual apartments and suites, where <br /> applicable, shall be clearly and legibly identified from the access road. <br /> 22. Based upon 86,732 square feet of Type V-A, sprinklered construction, the fire flow requirement is 2,625 <br /> gpm from three hydrants. <br /> 23.A portable fire extinguisher with a minimum U.L. rating of 2•A:10-B:C shall be provided within 75 feet of <br /> travei or. all floors of each building during construction and prior to occupancy. <br /> 24. An appreved automatic fire detection system shall be provided as required by City Ordinance No. 3021- <br /> 07, Chapter 16.76, of the Everelt Municipal Code. <br /> Plans for such system shall be submitted to the Fire Code Official for review and approval prior to <br /> installation. Submittal shall include cut sheets of all equipment intended for use. Appropriate trip tests, <br /> witnessed by a Fire Department Inspector, shall be performed, along with a certiFicate of completion, <br /> prior to final acceplance of the system. <br /> Fire alarm systems shall be installed according to NFPA Chapter 72. Installation of fire alarm <br /> components, including basic wiring, may not commence before plans are approved by the Fire <br /> Department Plan Reviewer. fire alarm drawings must be professionally rendered, in su�cient detail, <br /> and must be internally consistent. Riser diagrams must match installation plans and load calculations. <br /> Components must be listed and approved for use together. Changes to plans must include new <br /> drawings and calculations and must be approved by the Fire Department Plan Reviewer prior to <br /> installation. Fire alarm installation is subject to field inspection by a Fire Department Inspector. An <br /> approved set of plans and the Engineering & Public Services Department electrical permit must be <br /> present for any installalion inspeclion. <br /> Fire alarm systems shall be installed under permit of the City of Everett Engineering & Public Services <br /> Department. Eiectrical inspections and approval are required prior to calling for acceptance tests. Call <br /> (425) 257-881D for permit information. <br /> The absence of working phone lines for the alarm system will be cause for postponing Fire Department <br /> inspection and testing and shall result in denial of occupancy. <br /> 25. A ventilating hood and duct system with an approved automatic fire-extinguistiing system shall be <br /> provided in accordance with the Mechanical Code for commerciat-type food heat-processing equipment <br /> that produces grease-laden vapors. <br /> 26. An approved automatic suppression system shall be provided as required by City Ordinance No. 3021- <br /> 07, Chapler 16.76, of the Everett Municipal Code. The system must include a r�iechanical water gong <br /> bell. <br /> Plans for any such syslem shall be submitted to the Engineering & Public Services Department for <br /> examinalion and approval. Such plans shall include plans for the underground mains that will supply the <br /> sprinkler syslem. <br /> SI�J <br /> / <br />
The URL can be used to link to this page
Your browser does not support the video tag.