Laserfiche WebLink
KITIGI►TION RSQUIREp By gXISTING CODHS �1Np pRpINANCES <br /> 1. A fire hydrant is required within 20o driving feet but not <br /> closer than 50 feet, of every structure. (SEPA Public Services <br /> and Utilities Policies) <br /> 2. F411 standard half street improvements are required to Smith <br /> Street, includinq but not limited to, curb, qutter, sidewalk, <br /> street widening to 18 feet from center line, drainaqe controi <br /> and transitions per City Standards on the proposal�s full <br /> fronteqe per Ordinance 555-78 as amended. (SEPA Transportation <br /> Policies) <br /> 3. Curb, gutter, and sidevalk improvements are required to McDouqal <br /> 1►venue per City Standards on the propoeal�s full frontaqe per <br /> Ordinance 55-78 as amended. (SEPA Transportation Policies) <br /> 4• The driveway on Pacific ]�venue muat be removed and replaced with <br /> curb, qutter, and sidewalk per City Standards per Ordinance <br /> 555-78 as amended. (SEP1� Transportation Policies) <br /> 5. Special charges for connection to the sewer s <br /> With ordinance 984-83 are applicable. The actuel coatcshall�bt� <br /> computed by the buildinq Department per the ordinance in effect <br /> approvediplansdonctheddate of permitf�issuancepr�(SEP Public <br /> Services and Utilities Policies) I <br /> 6. A 2� foot sewer main eesement is required for the existinq sawe:r I <br /> main that crossea the site. A hold harmless aqreenent is <br /> required for the existinq sewer mnin. (SEPA Public Services and <br /> Utilities Policies) <br /> 7. The floor slab conatruction over the easement area of the seWer <br /> nein must be deaiqned to facilitate any repair/replaceaent of <br /> the main. Accese to the mnnhole is also required. <br /> e• On-site detention is required, OR, in lieu of providing on-site <br /> detention, payment to City �rainage Fund 340 is allowed per <br /> ordinance 670-80. (sEPA Public Services and Utilities <br /> Policies) <br /> 9• Parking must be per City Zoning Code and City Gesiqn and <br /> Construction StAndards. For the uses proposed (2,500 sf <br /> showroom, 19,269 sf warehouse and 3,654 sf office) , a minimum of <br /> 26 parking stalls are required. (SEPA Transportation Policies) <br /> iJ. Any broken/damaged sidewalk shall be repaired/replaced per the <br /> city Public Works inspector per ordinance 555-78 as amended. <br /> SEPA Transportation Policies) <br /> 11. Fire flow requirements for this buildinq is 2,870 gpm (ISO) . <br /> Fire flow must be provided per this requirement. (SEPa Public <br /> Services and Utilities Policies) <br /> 12. A landscape strip a minimum of 5 feet wide must be provided <br />