. . � � r� � � <br /> • Recreation Center- Fire flow requirement for this structure is 1,750 gpm; <br /> 45. Fire St�p�ression fS n�nkler)�y�tem (Buildin�� I_g) -An approved automatic <br /> suppression system shall be provided as required by City Ordinance No. 1902-92, <br /> Chapter 16.76, of the Everett Municipal Code. <br /> Plans for any such system must be submitted to the Building Department and the Everett <br /> Fire Department for examination and approval. Such plans must include plans for the <br /> underground mains that will supply the sprinkler system. <br /> As of January, 1991, sarinkler system permits are issued by the Building Department. <br /> Plan review fees aze assessed by the Building Department. No fee is assessed by the Fire <br /> Department. <br /> Above ground sprinkler piping must be hydrostatically tested as established in NFPA <br /> Standazd 13. Underground piping must be hydrostatically tested and flushed as <br /> established in NFPS Standard 24 for private fire mains. All such tests must be witnessed <br /> by a Fire Department inspector. Call 259-8710 to make an appointment for inspection. <br /> Contractors' materials and test certificates must be submitted to the Everett Fire <br /> Department prior to issuance of any Certificates of Occupancy. <br /> Call 257-8120 for more information. <br /> 46. Fire Alarf„ System (�j�ildin� 1-8. Rec. B�ildingl - An approved automatic fire detection <br /> system installed in accordance with City Ordinance No. 1902-92, Chapter 16.76,of the <br /> Everett Mwicipal Code. <br /> Plans for such a system shall be submitted to the Fire Marshal for review and approved <br /> prior to installation. Subminal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip tests, witnessed by a Fire Department inspector, shall be perfortned, <br /> along with a certificate of completion prior to acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Standard 72. <br /> i <br /> Fire alarm systems shall be installed under permit of the City of Everett Building � <br /> Department. Electrical inspections and approval are required prior to calling for � <br /> acceptance tests. Call (425) 257-8810 for pertnit infortnation. <br /> 47. Portable Fire Protection-A portable fire extinguisher with a minimum U.L.rating of 2- <br /> A:10-B:C shall be provided within 75 feet c�f travel on all fleors of each bu'slding during <br /> construction and prior to occupancy. <br /> i <br /> 48. Fire lanes must be provided as required in Evetett Municipal Code 46.v4. Fire lanes must <br /> be identified by red curbs with white stenciling stating "NO PARKING- FIRE LANE" <br /> and venical signs stating "NO PARKING- FIRE LANE -TOW AWAY ZONE." <br /> Location must be approved by the Fire Marshal. <br /> 49. The premises must be clearly identified by address at the street entry. Each building must <br /> be clearly identified so as to be visible and legible from the access road. Individual <br /> apartments and suites, where applicable, shall be clearly and legibly identified from the <br /> accessroad. <br />