My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY BASE FILE 2018-01-01 MF Import
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
BASE FILE
>
2300 MERRILL CREEK PKY BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2018 8:39:44 AM
Creation date
2/25/2017 10:23:04 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
228
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
22. Pour(�1) available fire hydrants are reouired for Phase 1 of the projecL They shall be locared <br /> within Z00 driving feet, but not closer than �0 feet, of every structure. The locaiion of hydrants <br /> shall be approved by the Fire Marshal. When Phase 2 (60,000 square feet) is constructed an <br /> additional two (2) hydrants will be required They shall be located within 200 driving feet but no <br /> closer than 50 feet of every structure. Location of hydrants shall be approved by the Fire Marshal. <br /> 23. An approved automatic suppression system shall be provided as required by City 0�divance No. <br /> 1902-92, Chapter 16.76, of the Everett Municipal Code. <br /> Pfans for any such system must be �ubmitted to the Building Department and the Everett rire <br /> Department for examination and approval. Such plans must include plans for the underground <br /> mains that will supply the sprinkler system. <br /> As of January, 1991, sprinkler system permits are issued by the Building Department. Plan review <br /> fees are assessed by the Building Department. No fee is assessed by the Fire Department. <br /> Above ground sprinkler piping must be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping must be hydrostatically tested and flushed as established in NFPS Sta��dard <br /> 24 for private fire mains. All such tests must be witnessed by a Fire Department inspector. Call <br /> 259-8710 to make an appointment for inspection. <br /> Contractors' materials and test certi�cates must be submitted to the Everett Fire Department prior <br /> to issuance of any Certificates of Occupancy. <br /> Call 259-8720 for more information. <br /> 24. An approved automatic fire detection system must bc provided as required by City Ordinance No. <br /> 1902-92, Chapter 16.76 of the Everett Municipal Code. <br /> Plans for such system must be submitted to the Fire Marshal for review and approval prior to <br /> installation. Submittal shall include cut sheets of all equipment intended for use. Appropriate trip <br /> tests, witnessed by a Fire Department inspector, must be perfortned prior to final acceptance of the <br /> s}•stem. <br /> Fire alarm systems shall be installed according to NFPA Standazd 72. <br /> Fire alarm systems must be installed under permit of the City of Everett Building Department. <br /> Electrical inspections and approval are required prior to calling for acceptance tests. Call 259- <br /> 8810 for pemtit information. <br /> 25. A portable fire extinguisher with a minimum UL rating of 2-A must be provided N ithin 75 1'eet of <br /> travel distance on each floor of all portions of each building during construction and prior to <br /> occupancy. <br /> 26. Fire lanes mus�be provided as required in Everett Municipal Code 46.44. Fire lanes must be <br /> identified by red curbs with white stenciling stating "NO PARKING - FIRE LANE" and vertical <br /> signs stating "NO PARKING - FIRE LANF. - TOW AWAY ZONE." Location must be approved <br /> by the Fire Marshal. <br /> 27. The premises must be clearly identified by the correct address at the street entry. Buildings must <br /> be clearly identified so as to be visible and legible from the access road. Individual suites, �vhere <br /> applicable, shall be cleazly visible and legibly identified from the access road. <br /> x <br />
The URL can be used to link to this page
Your browser does not support the video tag.