Laserfiche WebLink
. . <br /> � - <br /> 28. Any rockeries or retaining walls pr�posed NreqC�d setback areas must be in <br /> conformance with Secuon 39.15 • • the Zo ng e. The rockery along t6e south <br /> property line mast be reduced tu .,o" high, or a Review Process II application must <br /> be snbm►tted and approved by the Planning and Community Development <br /> , Director. If the rockery is located as shown, the applicant must demonstrate that <br /> landscaping requirements can still be met. <br /> 29. Building setbacks for [his proposal must be a minimum of 35 feet front yard, 15 feet <br /> ' side yard and 130 feet rear yard. Building height for buildings lo�.ated at least 300 feet <br /> � from residential areas shall be a maximum of 80 feet within .500 feet of the residential <br /> area and 120 feet in areas fiirther than 500 feet of the residential area. <br /> 30. Based upon 161,100 square feet of Type V-N, sprinklered construction, the fire flow <br /> requirement is 4,000 GPM. <br /> 31. When the required fire flow is over 2,500 gpm, the fire hydrant shall be served by a <br /> main which loops around the building or complex of buiidings and reconnecrs back into <br /> a distribution supply main. <br /> 32. A fire hydrant is required within 200 driving feet but not closer than 50 feet of every <br /> structure. The SW hydrant needs to be moved 200 feet to the north to give each <br /> I� building duee (3) hydrants within 200 feet. <br /> 33. Eir�Rnreccion (�Rrinkler)� stem - An approved automatic suppression system sl�al( <br /> be provided as required by City Ordinance No. 1902-92, EMC Chapter 16.76. <br /> �• Plans for any such system must be suomitted to the Building Department and Everett <br /> Fire Department for examination and approval. Such plans must include plans for the <br /> I' underground mains that will supply the sprinkler system. <br /> Above ground sprinkler piping must be hydrostatically tested as established in NFPA <br /> � Standard 13. Underground pipine must be hydrostatically tested and flushed as <br /> established in NPPA Standard 24 for private fire mains. All such tests must be <br /> witnessed by a Fire Department inspecror. Call 257-8123 to make an appointment for <br /> , inspection. <br /> Contractors' materials and rest certificates must be submitted to the Everett Fire <br /> Department prior to issuance of any Certificates of Occupancy. <br /> Call 257-8123 for more information. <br /> � 34. Pire Alarm System - An approved automaric fire detection system shall be provided as <br /> required by Ciry Ordinance No. 1902-92, EMC Chapter 16.76. <br /> Plans for such system shall be submitted ro the Fire Marshal for review and approvai <br /> f prior to installation. Submittal shall include cut sheets of all equipment intended fo; <br /> use. Appropriate trip tests, witncssed by a Pire Department inspcctor, shall be <br /> perfornicd, along with a certificate of completion, prior to final acceptancc of the <br /> � systcm. <br /> ' Pire alarm systcros shall bc instalicd according ro NFPA Standard 72. <br /> I <br /> � II <br /> 1 <br />