My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6300 MERRILL CREEK PKY BASE FILE 2018-01-01 MF Import
>
Address Records
>
MERRILL CREEK PKY
>
6300
>
BASE FILE
>
6300 MERRILL CREEK PKY BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2018 9:59:36 AM
Creation date
2/25/2017 10:39:20 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
6300
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
689
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Quadrant JN 97092 <br /> August 13, 1997 Page 4 <br /> An allowable bearing pressure of 2,500 pounds per square foot (ps� is appropriate for footings <br /> supported on competent, native soil or structural fill. A one-third increase in this design-bearing <br /> pressure may be used when considering short-tertn wind or seismic loads. For the above design <br /> criteria, it is anticipated that the total post-construction settlement of footings founded on <br /> competent, native soil, or on structural fill, will be about three-quarters inch, with differential <br /> settlements on the order of one-half inch in a distance of 100 feet along a continuous footing. <br /> Lateral loads due to wind or seismic forces may be resisted by friction between the foundation and <br /> the bearing soil, or by passive earth pressure acting on the vertical, embt�dded portions of the <br /> foundation. For the latter condition, the foundation must be either poured directly against relatively <br /> level, undisturbed soil or surrounded by level, structural fill. We recommend using the following <br /> design values for the foundation's resistance to lateral loading: <br /> Paremeter Design Value <br /> Coefficient of Friction I 0.50 <br /> ........._.._............................_.._...................._................�....__........_._._............... <br /> Passive Earth Pressure i 300 pcf <br /> Wlicru: (i) pcf Is Nounds pur cubic(ool,and(iq passivo oarlli <br /> prcssure Is computed using the aqulv�lent(luld density. <br /> If the ground in front of a foundation is loose or sloping, the passive earih pressure given above will <br /> not be appropriate. We recommend a safety factor of at least 1.5 for the foundation's resistance to <br /> lateral loading, when using the above design values. <br /> Seismic Considerations <br /> The site is located within Seismic Zone 3, as illustrated on Figure No. 16-2 of the 1994 Uniform <br /> Building Code (UBC). In accordance with Table 16-J of the 1994 UBC, the site soil profile is best <br /> represented by Profile Type S2. There is not a potential for seismic liquefaction of the glacial till <br /> soil at this site. <br /> Slabs-on-Grade <br /> The building floors may be constructed as slabs-on-grade atop native giacial till or structural fill. <br /> The subgrade soil must be in a firm, non-yielding condition at the time of slab construction or <br /> underslab fill placement. Any soft areas encountered should be excavated and replaced with <br /> select, imported, structural fill. <br /> All slabs-on-grade should be underlain by a capillary break or drainage layer consisting of a <br /> minimum 4-inch thickness of coarse, free-draining, structural fill with a gradation similar to that <br /> discussed later in PErmanent Foundation and Retainins� Wails. If the 12-inch topping of pit-run <br /> gravel is used, this 4-inch layer is not needed. In areas where the passage of moisture through the <br /> slab is undesirable, a vapor barrier, such as a 6-mil plastic membrane, should be placed beneath <br /> the slab. Additionally, sand should be used in the fine-grading process to reduce damage to the <br /> vapor barrier, to provide uniform support under the slab, and to reduce shrinkage cracking by <br /> improving the concrete curing process. <br /> GEOTECN CONSULTANTS,INC. <br />