Plans for any such system shall be submitted to the Building Department for examination and <br /> approval. Such plans shall include plans for the underground mains that will supply the sprinkler <br /> system. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA <br /> 13,NFPA 13P, or NFPA 13D system dcpending upon several factors. Spriokler installation shall <br /> not begin without an approved and stamped set ot plans from the Building Department. The <br /> Pire Department will also review the plans and shall field inspect the installation based only on <br /> approved plans that must bc on site. Changes to plans must be approved by both the Building and <br /> �ire Dcpartments. <br /> Aboveground sprinklcr piping shafl be hydrostatically tested as established in NFPA Standazd 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Standazd 24 <br /> for private fire mains. (Iielow-eround ainine must be installed bv Washinaton State Patrol <br /> Licensed Undereround Sprinkler linc certified "U" installers. For furthcr information,contact <br /> the State Fire Marshal's Oflice at(360)570-3134 or contact the Everett Firc Department at <br /> (425) 257-8123.) All such tests shall be witnessed by a Fire Department inspector. Call (425) 257- <br /> 8124 to make an appoinunec�t for inspection. <br /> Contractors' materials and test cerlificates sh111 be submitted to the Everett Fire Department prior to <br /> issuancc of any Certiftcates of Occupancy. <br /> Call (425) 257-8123 for more inforniation. <br /> I 1. SinFle ramily or Duplex- Singlc family or duplex structures that are required to have a fire sprinkler <br /> system may use a single domestic wnter mcter(see City of Everett Public Works Standard Drawing <br /> 502C). The size of the service meter shall be calculnted by the civil engineer or fire sprinkler designer <br /> who is solely responsible for these calculations. The City Public Works Depariment does not review <br /> thcse calculations and is not the auUiority having jurisdiction. Thc fire service side of the system must <br /> have a state-approved backtlow prevention devicc. <br /> 12. Constniction and dcmolition of buildings shall be in compliance�vith thc provisions of the 2003 <br /> Intemational Pirc Codc, Chaptcr 14. <br /> I 3. Pcnnits:,rc required from thc Pirc Dcpartment for removal and instullation of underground fuel tanks. <br /> 14. Abandoned tanks shall be pumped out and the fuel properly disposed of prior to removaL No product or <br /> rinse �vater may be disposed of in such a way that it could enter the storm drains system. <br /> 15. All fire alarni control panels (PACI') and sprinkler valves shall be in heated rooms or closets with <br /> standard man door access. Locations shall be npproved by the Fire Marshal's Office. <br /> 1 G. 'I'rash Collection- Dwnpstcrs over 1.5 cubic yards capacity shnll be located a minimum of 5 feet from the <br /> building �IPC 303.3.3, 2003 �ditionJ. <br /> s <br />