My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7211 RAINIER DR BASE FILE 2018-01-01 MF Import
>
Address Records
>
RAINIER DR
>
7211
>
BASE FILE
>
7211 RAINIER DR BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2019 3:44:43 PM
Creation date
2/27/2017 8:02:09 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER DR
Street Number
7211
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
505
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9. A fire hydrant is required within 200 ft of every structure but not closer than 50 ft <br /> 10. On-site watermain will be staked within an easement to the City. The easement <br /> will be submitted to the City prior to issuance of permits. <br /> 1 l. As-builts of storm sewer, s�nitary sewer, and water systems will be required to be <br /> submitted per City Design and Construction Standards and Specifications. <br /> 12. A permit is required for the destination of any fill dirt from this site that is to be <br /> deposited within the city limits. <br /> 13. A pedestrian connection from t�:e proposed project to the eristing sidewalk system <br /> is required. The walkway as shown on the submitted site plan appears to meet this <br /> requirement. <br /> 14. Provisions for a covered secured area for parkine bicycles is recommended. <br /> 15. A Performance Guarantee is required for any improvements to be donc within the <br /> Fainier Ave right-or-way prior to any building permit bein� issued. <br /> 16. On-site detention is required for stormwater runoff from this site per ciry standards <br /> 17. Treatment of stormwar - nmoff from the paved areas must occur, per C:iiy <br /> standards, prior to dischTr�e of the stormwater from the site or to a stream �r <br /> wedand. Srormwarer detention/rerention, qualiry prorection, and treatmer <br /> requirements for this project shall be those requirements in eft'ect at th�: time c <br /> application for Public �'�'orks permits. C.�rrendy, srormwater treatment i� require i <br /> when 10,000 squere feet of pa��ement is created by a project such as �hi: <br /> townhome project and tivee options for stonmvater treatmei�t are presented in th� <br /> current Ciry standards. The least preferred option is allowed only if the firs tw., <br /> options are infeasible in the opinion of the Public Worr:s Department. The options <br /> for stormwater treatment are, in order of preference: <br /> 1) an infiltration basin designed and constnied according .o City standards, if <br /> suitable soils exist on the site. <br /> 2) a wetpond designed and constructed to City standards. <br /> 3) a baftle-type oil/water separator follo���ed by a �'esetated swale, both <br /> designed and constructed according to City standards. The presence of the creek <br /> on this site indicates that the soils may not be suitable for an infiltration basin. If <br /> an infiltration basin is not feasible, a �vetpond will be req4ired. No stormwater <br /> facilities, with the exception of necessarv discharge syste:ns, rr�y be located inside <br /> wetland or stream butl'er areas. � <br />