Laserfiche WebLink
required vegetated swales, wetponds, detention ponds, rockeries and <br /> retaining walls, and gradir,g at Z foot intervals. Irrigation systems must be <br /> provided in all landsc�ped areas per Section 35.130 of the Zoning Code. A <br /> 2 year maintenance assurince device must be provided for the landscaping <br /> per Section 35.130B of the Zoning Code. <br /> 33. A minimum of 3,300 square feet of open space is ren,uirc.i on tlie site per Section <br /> �5.030 ofthe Zoning Code. �alculations for open space areas must be provided <br /> on the plans submitteo ior Building Permits. <br /> 34. On-site recreation facilities must be provided per Section 15.110 of the Zoning <br /> Code. For the 22 units proposed, with unit sizes under 600 square feet, the project <br /> will have a recreation impact of .22 acres. Prior to the issuance of Building <br /> Permits, the Planning Depanment must approve a plan for on-sit� recreation <br /> facilities. As part of the building permit application, the Applicant must submit a <br /> recreation plan including standards and specifications for recreation areas and <br /> equipment, both inside and outside the buiiding, including pictures of proposed <br /> equipment. If suf£cient infonnation is not knc+�.vn at cime of submittal for building <br /> permits, minimum specifications or e�amples must be provided. Prior to the <br /> issuance of Building permits, the Planning Department must approve a plan for on- <br /> site recreatiun facilities. Tot lots must be Iocated in central areas, where adequate <br /> supervision of children can be provided. <br /> 35. Building facade modulation and roof line variation must be provie;ed per Section <br /> I5.050 of the Zoning Code. The m�ximum permitted wall and roof lengths <br /> without building facade modulation is 30 feet. <br /> 36. A fire hydrant is required within 300 driving feet, but not closer than 50 feet, of the <br /> structure. Two 2vailable fire hydrants are required. The location of the hydrants <br /> as shown on the site plan are acceptable. <br /> 37. My security fence erected around the construction site must be located so as to <br /> not obstruct any existing hydrant, tire protection equipment, or Fire Department <br /> access. If Fire Depanment access is obstructed, gates or other openings rnust be <br /> provided for access. <br /> 33. A portable fire extinguisher with a minimum UL rating of 2A must be provided <br /> within 75 feet travel distance on each fluor of all portions of each building during <br /> construction. <br /> 39• An approved automatic fire detection system must be provided as required by City <br /> Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. Plans for <br /> such system must be submitted to the Fire Marshal for review anu approval prior <br /> to installation. Submittal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip tests, witnessed by a Fire Department inspector, must be <br /> performed prior to finai acceptance of the system. <br /> Fire alarm systems must be installed u!ider permit of the City of Everett Building <br /> Department and accordin� to NFPA Standard 72. Electrical inspections and <br /> approval are required prior to callins for acceptance tests. Call 259-8810 for <br /> permit information. � <br /> 40. 'fhe premises must be clearly identified by address at the street entry. Each <br /> building must be clearly identified so as to be visible and legible from the access <br />