My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5104 S 2ND AVE 2018-01-01 MF Import
>
Address Records
>
S 2ND AVE
>
5104
>
5104 S 2ND AVE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2019 3:27:01 PM
Creation date
3/8/2017 12:18:19 AM
Metadata
Fields
Template:
Address Document
Street Name
S 2ND AVE
Street Number
5104
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Check HB-44775/B-44776 <br />August 22, 1994 <br />Page 3 <br />�/15. A clear space 30 inches wide, 29 inches high and 17 inches in depth shall be <br />provided under each lavatory. Section 3106(K)7c. A clear floor space not less <br />than 30 inches wide and 48 inches deep is required in front of lavatories and <br />sinks. Section 3106(k)7a. <br />✓16. <br />✓17 <br />The bottom of at least one mirror shall be within 40 inches of the floor. Section <br />3105(b)3 and 3106(k)8. <br />Hand drying equipment and toilet accessories shali be placed within 40 inches of <br />the floor. Section 3106(k)8. <br />,/t8. In mu1G-story buildings or portions thereof required to be accessible by SecGon <br />3103, at least one accessible elevator shall serve each level, including <br />mezzanines. Section 3105(g). The lift must be an elevator that complies with <br />Chapt. 296-81 Wa. Admin. code <br />�9. <br />✓20. <br />21. <br />22. <br />23. <br />�4. <br />25. <br />Controls, operating mechanisms and hardware shall be accessible in accordance <br />with Section 3106(c). Section 3105(d)8. <br />Alarm systems shall include both audible and visible alarms and shall be located <br />per Section 3105(d)9. <br />Accessible pazking stalis must be 8'0" minimum wide with a 5' minimum <br />access aisle. <br />Provide accessible pazking signage per Sec. 3107(c). <br />Provide sit� plans with grade elevations and the accessibie route of travel <br />illustrated. <br />Exhaust fans must vent to the exterior of the building. <br />An exit stair or ramp must be provided from the porch areas. <br />p/iHtl/iI� 26. Provide swctural calculations <br />V27 <br />� <br />Indicate the method used to introduce fresh air into the building. <br />The prescriptive path chosen (path I) allows 10% window azea. The window <br />area calculates to 11.17`�0. Revise path or window area. <br />