Laserfiche WebLink
A. Lot Status —All parcels appear to be legal lots and meet the minimum lot requirements for <br />the R-2 zone. The City certified the lots in a letter dated July 1997. <br />B. Environmentally Sensitive Area Findings: <br />• The parcels consist of unplatted lots. The lots are bounded by 1-5 to the west, 491h <br />Street to the south and S. Fourth Avenue to the east: <br />• The site is primarily forested, with both an understory (shrub) and overstory canopy <br />(primarily deciduous trees,). There are some disturbed areas near the 1-5 right-of-way <br />and some blackberries. The vegetation on the site is well documented in greater detail <br />in the Wetland Delineation report, revised December 23, 2008. <br />• The site contains a Category III scrub -shrub wetland, located on the lots north of the <br />proposed duplex site. Under EMC Chapter 19.37.140, Category III wetlands scoring <br />less than 19 in habitat value are required to have a buffer of 60 feet consisting of native <br />vegetation. The site also contains a Type F stream (Bigelow Creek). Type F streams <br />are required to have a buffer of 150 feet when the buffer is in a disturbed state. The <br />stream is located approximately 150 feet south of the proposed duplex site. The wetland <br />and stream are shown in the wetland report. The proposed duplex and road access <br />would leave an approximately 20-foot buffer from the wetland. <br />• There is a steep slope (greater than 40%) that extends from just south of the proposed <br />duplex site and forms a portion of the Bigelow Creek ravine. The proposed duplex <br />would have a 15-foot building setback from the top -of -slope. A soils report dated August <br />5, 1999 was provided with the original application. This report concludes that the top -of - <br />bank setback can be reduced to 15 feet without impacting the slope or the future <br />residence. <br />• Together the stream, wetland and steep slope areas result in almost all of the site being <br />classified as critical area or buffer. It would not be possible to locate a new residential <br />structure on the site that meets the protective requirements of EMC Chapter 19.37. <br />REASONABLE USE EVALUATION C., 1TERIA This section addresses the reasonable <br />use criteria In Subsection 37.050.B.2 of the Zoning Code <br />1. There is no other reasonable use or feasible alternative to the proposed <br />development with less impact on the environmentally sensitive area. <br />Finding: Over the last several years, many different development scenarios have been <br />discussed between the applicant and the City. One prior proposal included a 5-lot <br />residential short plat. Another proposal included construction of several duplexes on the <br />site. In each case, the City determined that substantial impacts on environmentally <br />sensitive areas would occur and that mitigation of these impacts would need to be <br />provided. Further difficulties included providing adequate fire access, drainage and <br />utilities to the site. <br />Conclusion: Other alternatives have been examined by the City and were determined <br />to have significant impacts on wetlands and steep slopes. The proposed duplex can be <br />constructed so as to minimize these impacts and provides turther mitigation through <br />buffer enhancement. <br />CR 2930 Wetmore, Suite 8-A, live"e(t, 1\'A 98201-4044 9 (425) 257-8731, 1^1s (425) 257-8742 <br />