My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4729 VIEW DR 2016-01-01 MF Import
>
Address Records
>
VIEW DR
>
4729
>
4729 VIEW DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2017 10:25:38 AM
Creation date
3/8/2017 10:25:21 AM
Metadata
Fields
Template:
Address Document
Street Name
VIEW DR
Street Number
4729
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 2 of 4 <br /> C.O.E. # S�/S�o <br /> Date <br /> 12 Specify on the plans that exterior joints shall be sealed, caulked, gasketed, or weatherstripped to <br /> Gmit air leakage at the foliowing locadons: 502.4.3 <br /> a. windows and door frames <br /> b. openings between w�alls and foundation <br /> c. between walis ar.d roof <br /> d. openings at penetration of utility services <br /> e. all other openings in the building envelope ' <br /> 13 Note on the plans that recessed lighting 6xtures which are installed in the building envelope shall <br /> comply with provisions of WSEC 502.4.4. <br /> � Note on the plan� that all heating ducts in unconditioned spaces are to be insulated to a <br /> minimum of R-8. All ductwork seam joints are to be taped and sealed and fastened with a <br /> minimum of the fasteners. 503.10 <br /> � Specify on plans that non-recirculating hot and cold water pipes located in unconditioned space <br /> shall be insulated to R-3 minimum. 503.I 1 <br /> � Provide a readily accessible, automatic or manual shut off switch, and a thertnostat. 503.83.1, <br /> 503.8.1 <br /> 17. Note on the plans that showers shall be equipped with flow control devices to limit the total <br /> water flow to 2.5 gpm. 504.8 <br /> 18 Note on the plans ihat water heaters shall meet the requirements of the 1987 NAECA and shall <br /> be so labeled. Electric water heaters in unconditioned spaces shall be placed on an <br /> incompressible, insulated surfa e with a minimum thermal resistance ofR-10. Sj�Ow WA7� <br /> �-1,�ia�:.2 Lacn7wti�S� O� P�nnJS. <br /> � The floodceiling joists are not deep enough to accommodate the insulation shown and a <br /> minimum I" air space above for venting. Provide adeq!iate depth and venting. <br /> � Provide heating and cooling design loads ca�culations for sizing the HVAC system per WSEC <br /> 503 2.1. <br /> ( 2yJ Building mechanical systems shall be sized to no greater than 150% of the heating and cooling <br /> � design loads. Provide calculations. 503.2.2 <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.