Laserfiche WebLink
. . . � <br /> Page 4 of 4 <br /> C.O.E. # So/SG <br /> Date � <br /> 10 Note on the drawings that all structural panel components of the house wch as softwood, <br /> plywood, particle board, wafer board and oriented strand board shdl be idrntiSed ss <br /> "EXPOSURE l", "EXTFRIOR" or"HfJD-APPROVED". 400.1 <br /> � Specify on the plans that all solid fuel burning appliances shall be provided with the following: <br /> a. Tight fitting glass or metal doors. <br /> b. An outside source of combustion air directly connection to the firebox, or tested and Gsted <br /> per HiJD carbon monoxide perfortnance requiizments. <br /> � Fireplaces shall be provided with each of the followin;: <br /> a. Tightly fitting flue dampers, operated by a readily accessible manual or approved automatic <br /> control. <br /> b. An outside source for combustion air-ducted into the 6rebox, a minimum of six square <br /> inches and an operable outside air duct damper. <br /> � Note on the plans that the builder shall provide a three month etched tract radon monitor, <br /> installation instructions and radon information sheets at the final inspection. <br /> ADDITIONAL COMMENTS <br /> Etev. ;2-�I-95 <br /> JE{L(ST.doc � <br /> ( <br />