My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1918 WALL ST 2018-01-02 MF Import
>
Address Records
>
WALL ST
>
1918
>
1918 WALL ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 11:40:40 AM
Creation date
3/8/2017 1:26:51 PM
Metadata
Fields
Template:
Address Document
Street Name
WALL ST
Street Number
1918
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
769
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MEMORANDUM <br />Page 4 <br />November 25, 1983 <br />Item #15: Suspended ceiling systems comply as specified. See Section <br />09100, 09260, 09280, and 09510. <br />Item 516: Agree. Plastic laminate is specified "fire -rated." See <br />Section 06400, page 14. Wall coverings specified meet <br />requirements for Class I. <br />Item #17: Agree. Liquid marking boards and tackboards are intended to <br />comply with flame spread requirements. <br />Item #18: The relatively small roof area and low parapet height served <br />by the scupper on detail 6/A4.2 will not present a structural <br />Problem in the unlikely event the scupper becomes clogged. <br />The roof is designed to support more load than this small <br />buildup of water. Therefore, we feel one scupper as indicated <br />is more than adequate. <br />Item -19: Agree. Detail will be revised to omit the screen and provide <br />a metal gravel stop. (Change order required.) <br />Item =20: Each housing module is provided with fire hate cabinets with <br />11" hose to serve areas not provided with automatic sprinklers <br />(cells). Fire protection plans, including sprinkler system, <br />hose cabinets and smoke exhaust system were reviewed and <br />approved by the County, the Everett City Building Department <br />and the City Fire Marshall at a meeting at the Building <br />Department on December 16, 1982. We feel the building design <br />complies with the intent of the Building Codes and in fact may <br />exceed normal requirements. Class I standpipes are provided <br />throughout the building. <br />Item 521: Agree. Precast floor panels will comply. See structural <br />comments. <br />Item #22: Agree. Door #S203 will be changed to 1;-hour rating as <br />required. (Change order required.) <br />Item #23: Agree. Wall construction will be changed to 6" CMU wall to <br />achieve a 2-hour rating. (Change order required.) <br />Item #24: Design complies. Wall type "0" at the mechanical rooms <br />mentioned is grouted full at all cells as a security line. <br />Item #25: Design complies. See specifications. Section 11400. Hood <br />does not penetrate floor. The kitchen hood ductwork is <br />enclosed within a 2-hour fire resistive enclosure. <br />
The URL can be used to link to this page
Your browser does not support the video tag.