number first. The system shown may cause serious enars to be made in the field. <br /> Comment noted. Please refer to revised drawings showing new door and <br /> hardware schedule. <br /> 5. Fire protec'ion shall be provided for the building during construction. Details and <br /> procedures should be provided in accordance with Section 904.4 <br /> Comment noted. Please refer to revised drawings showing new details and <br /> reference notes. <br /> 6. Protection of pedestrians during construction per Section 3303 is required. Details <br /> and requirements should be coordinated with the Kathy Fox, Public <br /> Services/Engineering Department, City of Everett, and the Civil Engineering Division <br /> of the Building Departrnent, City of Everett. <br /> Comment noted. Please refer to revised drawings showing new details and <br /> reference notes. <br /> Z. Changes in the submitted building may require a resubmission to the Planning <br /> Uepartment, City of Everett for evaluation and compliance. Gary Doughty, Planning <br /> Department, (425) 257-8731, should be contacted for the requirements. <br /> Comment noted. Gary has been presented with the proposed modificatlons and <br /> is taking no exceptions as long as we meet the overall area rewquirement for open <br /> space/recreation. Gary will review and approve the submitted revisions. <br /> Allowabl� Ana <br /> Floor area is the area included within the surrounding exterior walis of a building or <br /> portion thereof, exclusive of vent shafts and courts. The fioor area of a building, or <br /> portion thereof, not provided with surrounding walls shall be the usable area under the <br /> horizontal projection of the roof or floor above per Section 20�. Based on this <br /> definition, the floor area of all decks and balconies, which have a deck, balcony or <br /> roof above, should be included in the allowable area calculations. The westem <br /> portion of the building (ailey building) is therefore over allowable area. Secdon 504. <br /> 2. The aggregate floor area of inezzanines within a room should be limited to one <br /> third of the floor area of the room in which they are located per Section 507. By my <br /> calculations, the following units are over area as shown (note that exterior walls and <br /> interior stairs were subtracted from the equation): <br /> I ill��l '.I11\�1f9�J�.I 1�,��,"y��"�1�1, <br /> � � , � . i .. .. .... ,,� -r�i u�r:��„�a�.� <br /> NIICRPI.III�Ii;�l'�i�NiiRP��'i;f f;�IPIII�;D.�lf,l!�IIDiC1fEUf,�p;l':1RCHITGCTI�R� !1�I+1CRP��1111f,�I11��iIRpE�161��SRI�IIi����IG11L1111SC�I�pG�IG1� <br />