Laserfiche WebLink
shear walls and wall offsets or on-site changes ma}� reduce the structural int:griry of <br /> the lateral force resisting system. Such proposals should also be submitted to the <br /> Engineer of Record. <br /> 11. Section BB/A5.2 shows a beam suppo�ting the exterior wall of the southern stair <br /> enclosure. This beam (and sttucture suppoRing the beam) should be shown as <br /> individually protected for two-hour fire resistance. Section 704.2.6 <br /> 12. Fire blocking should be shown at the interconnecdons of the floor and wall <br /> assemblies in detail9/5-16. Section 708.2 <br /> 13. Details of interior non-bearing paztitions within the apaztments should be provided. <br /> Section 601.5.2.2 I <br /> 14. Details of the connections and construction of the juncture betwxn the <br /> balconies/decks and the floors/walis should be provided. <br /> 15. Eave overhangs shall be constructed for one-hour requirements in ereas where <br /> opening protection is required. Secdon 705 <br /> 16.The bearing walls should be clearly delineated on the plans for the pu�pose of <br /> providing through penetration protection. Section 709.6 <br /> 17. It should be detailed on the plans how fire-resistive walls requiring protected <br /> openings and beazing walls are protected with firo stops requiring F and/or T ratings <br /> for both membrane and ttuough penetrations. Details and informadon should be <br /> provided on the plans, along with the appropriate approval numbecs. Sections 709.6, <br /> 709.7 &7l4 <br /> 18. Details should be provided which show the method of protecdon for all proposecl <br /> penetrations of the ceiling membrane per Section 710.2. <br /> 19. Details of the clothes dryer and kitchen stove ezhaust duct shafts should be provided <br /> per Section 710.2. Note that dampers are not permitted for these ducts per the UMC. <br /> 20. Floors should be continuous without openings or penetrations unless it is noted and <br /> detailed on the plans that penetration of floors will be protected with through- <br /> penetration fia stops installed to provide an F or T rating, as well as a listing showing <br /> each proposed fire stop. Secdon 710.3 <br /> 21. Per Section 713.13, a sign shall be displayed permanently neaz or on each required <br /> fire door (rated at 3/4 hour and above) in letters not less than I inch high to read as <br /> follows: FTRE DOOR <br /> DO NOT OBSTRUCT <br />