Laserfiche WebLink
, . c <br /> Christopher Day <br /> Plan Check J/55288 <br /> June 17, 1997 <br /> Page 2 of 5 <br /> 8. Show location of 22" x 30" attic access with 30" minimum headroom. (1505.1 <br /> UBC) <br /> 9. Provide tempered glass at required hazardous locations/2406.4 UBC. Show on <br /> plans. <br /> 10. Provide section and details of stairway showing: <br /> a. Framing (stringer size, bracing connections, footings). <br /> b. Enclosed useable space under stairway requ'rres one-hour construction on <br /> enclosecl side. <br /> c. Guardrail construction and spacing of intermediate railings. <br /> 11. Show under tloor ventilation opening size and Iocations equal to 1 square foot for <br /> each 150 square feet of under floor area. Show the required net area calculation <br /> assuming approximateiy 75'% of the vent azea is net area unless the actual net azea <br /> is given from the manufacturer, <br /> 12. Provide foundation plan, cross section, framing plan, roof framing plan for <br /> attached garage. <br /> 13. Provide section, details and plan for bridge between house and guest bedroom. <br /> l4. Provide foundation plan for house. Foundation plan shall be completely <br /> dimensioned. Show crawl space access. <br /> 15. Provide detail of intermediate supports. Positive connection shall be provided to <br /> ensure against uplift and laterai displacement (2324 UBC). <br /> 16. Provide note that fireplace is a listed and labeled appliance. <br /> 17. Show all posts including built-up studs. <br /> 18. Cross reference atl calculations for joists, beams, shear walls, etc. to framing/tloor <br /> plans. <br /> 19. Show at least one inch of vent space above the ceiling insulation with cross <br /> ventilation. 502.1.4.5 <br /> 20. Specify on the plans the type of vapor retarders to be instafled on the warm side of <br /> the msulation for ceiling, walls and floor. 502.1.6.1 <br />