My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3209 SHORE AVE 2016-01-01 MF Import
>
Address Records
>
SHORE AVE
>
3209
>
3209 SHORE AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2017 6:23:16 PM
Creation date
3/9/2017 6:23:03 PM
Metadata
Fields
Template:
Address Document
Street Name
SHORE AVE
Street Number
3209
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. , <br /> < ( <br /> Christopher Day <br /> Plan Check 1155288 <br /> June 17, 1997 <br /> Page 3 of 5 <br /> 21. Note on the drawings that insulation shall be provided with clearances for venting, <br /> chimneys, lights, etc., in accordance with the manufacturer's specifications. <br /> 502.1.4.3 <br /> 22. Specify on the plans that exterior joinGs shall be sea!ed, caulked, gasketed, or <br /> weatherstripped to limit air leakage at the fullowing locations: 502.4.3 <br /> a. Windows and door frames. <br /> b. Openings between walls and foundation. <br /> c. Between walls and roof. <br /> d. Openings at penetndon of utility services. <br /> e. All other openings in the building envelope. <br /> 23. Note on the plans that recessed lighting fixtures which are installed in the building <br /> envelope shall comply with provisions of WSEC 502.4.4. <br /> 24. Note on the plans that all heating ducts in unconditioned spaces are to be insulated <br /> to a minimum of R-8. All ductwork seam joints are to be taped and sealed and <br /> fastened with a minimum of the fasteners. 503.10 <br /> 25. Specify on plans that non-recirculating hot and wld water pipes located in <br /> uncondinoned space shall be insulated to R-3 minimum. 503.11 <br /> 26. Provide a readily accessible, automatic or manual shut off switch, and a thermostat. <br /> 503.8.3.1, 503.8.1 <br /> 27. Note on the plans that showers shall be equipped with flow control devices to limit <br /> the total water flow to 2.5 gpm. 504.8 <br /> 28. Note on the plans that water heaters shall meet the reyuirements of the 1987 <br /> NAECA and shall be so labeled. Electric water heaters in unconditioned spaces <br /> shall be placed on an imcompressible, insulated surface with a minimum thermal <br /> resistance of R-10. <br /> 29. Source specific fans ue required in each kitchen, bathroom, water closet, laundry <br /> facility, indoor swimming pool, spa, and other rooms where excess water vapor or <br /> cooking odor is produced. Specify the fan locations and sizes at minimim of 50 <br /> cfm at 0.25" water gauge for bathrooms and laundries and 100 cfm at 0.25" for <br /> kitchens. <br />
The URL can be used to link to this page
Your browser does not support the video tag.