My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 TOWER ST GRAY WOLF HALL 2018-01-01 MF Import
>
Address Records
>
TOWER ST
>
2000
>
GRAY WOLF HALL
>
2000 TOWER ST GRAY WOLF HALL 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2019 1:11:31 PM
Creation date
3/10/2017 5:29:09 AM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
GRAY WOLF HALL
Notes
UNDERGRADUATE EDUCATION
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
378
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plans (or such system shall be submitted to the Fire Alarshal for revie�v and approval prior <br /> lo installation. Submitlal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip tests, witnessed by a Fire Department inspector, shall be performed, aiong <br /> with a certificate of compietion, prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Standard 72. !�ctallation of fire <br /> alarm components, including basic wiring, may not commence before plans are <br /> approved by the Fire Department Pian Revis:uer. Fire aiarm drawings must be <br /> pro(essionally rendered, in sufficienl detail, and mu�t be internally consistent. Riser <br /> diagrams must match instailalion plans and load ca�culations. Components must be listed <br /> and approved for use togelhr:r. Changes to plans must include ne�.v drawings and <br /> cal�ulations and must be approved by the Fire Cepartment Plan Reviewer prior to <br /> installalion. Fire alarm installation is subjecl to fieid inspection by a Fire Department <br /> Inspectoc An approved set of plans and lhe Buildiny Department electrical permit must be <br /> presenl (or any install-.',on inspeclion. <br /> Fire alarm systems shall be installed under permit o(thr, City of EvereU Building <br /> Depanmenl. Eleclrical inspections and approval are raquired prior to callinu for <br /> acceptance tesls. Call (425) 257-8810 for permit inf�irmation. <br /> The absence of working phone lines for the a;arm system will be cause for <br /> postponing fire department inspection and iesting and shall result in denial of <br /> occupancy. <br /> 12. Fire £upnression (Sprinkler) Svstem - An appro��ed aulomatic suppression system shall be <br /> provided as required by City Ordinance No. 1902-92, Chapter 16.76, of the Everetl <br /> Municipal Code. The system must include a mechanical water gong bell. <br /> Plans for any such system shall be submilted to ihe Buildinc� Department for examination <br /> and approval. Such plane shall include plans for the underground mains lhat will supply <br /> lhe sprinkier system. <br /> The type o(sprinkler to be installed will be determined by the Building Official. It may be <br /> an NFPA 13, NFPA 13R, or NFPA 13D system depending upon sev�ral factors. <br /> Sprinkier fnstallation shall not begin without an approvr,d and stamped set o( plans <br /> from the Building Department. The Fire Department will also review ihe plans and shall <br /> (ield inspect Ihe installation based only on approved plans lhat must be on site. Chanyes <br /> to plans must be approved by both lhe Duilding and Fire Departmenls. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA <br /> S�andard 13. Underground piping shall be hydrostatically tesled and flushed as <br /> established in NFPA Standard 24 tor privatc fire mains. (Below-qround pipinq must be <br /> installed bV Washin�ton State Patrol Licensed Underground Sprinkier line certified <br /> "U" instailers. For further information, contact the State Fire Marshal's Office at <br /> (360) 5703134 or contact the Everett Fire Department at (425) 257-8125.) All such <br /> lests shall be wilnessed by a Fire Department inspector. Call (425) 257-f3124 to make an <br /> appointmenl (or inspeclion. <br /> Contractors' niaterials and test certificates shall be submitted to th�,� Everett Fire <br /> Departrnent prior to issuance oi any Certi(icales oi Occupancy. <br /> q <br /> �13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.