Laserfiche WebLink
of three sets of results for evaluation. If enough backup samples <br /> are not available, the Contracting Agency will select core sample <br /> locations from the Roadway in accordance with WSDOT Test111 <br /> Method T 716, take cores from the roadway in accordance with <br /> WSDOT SOP 734, and test the cores in accordance with WSDOT <br /> SOP 737. <br /> 2The Nonstatistical Evaluation tolerance limits in Section 9-03.8(7) <br /> will be used in the calculation of the PF,. <br /> 3The maximum CPF shall be 1.00. <br /> 1 <br /> 2 5-04.3(9)D Mixture Acceptance—Visual Evaluation <br /> 3 Visual Evaluation of HMA mixture will be by visual inspection by the <br /> 4 Engineer or, in the sole discretion of the Engineer, the Engineer may <br /> 5 sample and test the mixture. <br /> 6 <br /> 7 5-04.3(9)01 Mixture Visual Evaluation — Lots, Sampling, Testing, <br /> 8 Price Adjustments <br /> 9 HMA mixture accepted by Visual Evaluation will not be broken into <br /> 10 lots unless the Engineer determines that testing is required. When <br /> 11 that occurs, the Engineer will identify the limits of the questionable <br /> 12 HMA mixture, and that questionable HMA mixture shall constitute a <br /> 13 lot. Then, the Contractor will take samples from the truck, or the <br /> 14 Engineer will take core samples from the roadway at a minimum of <br /> 15 three random locations from within the lot, selected in accordance <br /> 16 with WSDOT Test Method T 716, taken from the roadway in <br /> 17 accordance with WSDOT SOP 734, and tested in accordance with <br /> 18 WSDOT SOP 737. The Engineer will test one of the samples for all <br /> 19 constituents in Section 5-04.3(9)B3. If all constituents from that test <br /> 20 fall within the Job Mix Formula Tolerances (for Visual Evaluation) in <br /> 21 Section 9-03.8(7), the lot will be accepted at the unit Contract price <br /> 22 with no further evaluation. <br /> 23 <br /> 24 When one or more constituents fall outside those tolerance limits, the <br /> 25 other samples will be tested for all constituents in Section 5- <br /> 26 04.3(9)B3, and a Job Mix Compliance Price Adjustment will be <br /> 27 calculated in accordance with Table 15. <br /> 28 <br /> Table 15 <br /> Visual Evaluation —Out of Tolerance Procedures <br /> Comply with the Following <br /> Pay Factors' Section 5-04.3(9)B4 <br /> Composite Pay Factors2 Section 5-04.3(9)B5 <br /> Price Adjustments Section 5-04.3(9)B6 <br /> 'The Visual Evaluation tolerance limits in Section 9-03.8(7) will <br /> be used in the calculation of the PF;. <br /> 2The maximum CPF shall be 1.00. <br /> 29 <br /> 30 5-04.3(9)E Mixture Acceptance — Notification of Acceptance Test <br /> 31 Results <br /> 32 The results of all mixture acceptance testing and the Composite Pay <br /> 33 Factor (CPF) of the lot after three sublots have been tested will be <br /> 34 available to the Contractor through The Contracting Agency's website. <br /> I <br /> AMENDMENTS TO THE 2016 STANDARD SPECIFICATIONS BOOK <br /> Revised: 8/11°5 <br />