My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 HEWITT AVE EVERETT EVENT CENTER 2016-01-01 MF Import
>
Address Records
>
HEWITT AVE
>
2000
>
EVERETT EVENT CENTER
>
2000 HEWITT AVE EVERETT EVENT CENTER 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2017 2:11:53 PM
Creation date
3/16/2017 8:00:07 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2000
Tenant Name
EVERETT EVENT CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
319
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. i <br /> Ltr. Dcric Von Schlicder <br /> May 14, 2003 <br /> Page 2 <br /> 3. The desien and engincering of the conswction supporting the operable walls in the <br /> ballroom and entry lobby should be shown as a deferred submittal on the cover sheet. <br /> Section 1063.4.2 <br /> 4. The proposcd location of alcohol storage should be shown. It should be shown as an S-2 <br /> Occupancy if it is stored alone, or may be within an S-1 Occupancy if stored with <br /> combustible goods. An occupancy separation may be required. Section 311.1 <br /> Construction <br /> 1. Suspended ceiling systems are designed to be level (to within U8" over 12') and be attached <br /> to sWcture at the perimeters. The proposed clouds are sloping and detached from the walls. <br /> The manufacturer's listing must be provided which shows the system has been approved for <br /> this proposed conGguration. UBC Standard 25-2, Section 25.210 <br /> 2. Various suspended ceiling details on sheet A11.0 show a horizontally stacked and/or <br /> discontinuous, cantilevered ceiling system (such as for a light cove or window shade). The <br /> manufacturer's listing must be provided which shows the system has been approved for <br /> these proposed configurations. <br /> 3. Requirements for lateral bracing and compression struts for the suspended ceilings should be <br /> provided on the plans. UBC Standard 25-2, Section 25.212.3 <br /> d. All rated walls should have thcir listing shown on the plans (all partitions must be minimum <br /> one-hour rated unless they are within an office or store space). Sections 601.1, 601.5.2.1 & <br /> 1703.1 <br /> 5. Note 12 on sheet A8.0 should be revised to require fire-retardant treated wood, or a non- <br /> combustible blocl:ing. Section 602.1 <br /> G. A detail should be added for required backing in stair and shaft walls showing a non- <br /> combustible material. Section 602.1 <br /> 7. Listing U433 for wall type N6/A8.0 requires Type C for two layers of'/z"GWB. <br /> S. The fire protection of the two-hour wall should be continuous through the intersection <br /> sho�+�n in Detail 9/Al 1.0. Section 709.1 <br /> J. The Floor of the toilet rooms on the first Floor should be a smooth, hard nonabsorbent surface <br /> such as portland cement, concrete, ceramic tile or other approved material thut extends <br /> upward onto the walls at least � inches. Section 807.1.1 <br /> 10. The toiict room kcynotes on sheet A6.2 should be completed. <br /> ll � <br /> �I ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.