My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 37TH ST 2018-01-02 MF Import
>
Address Records
>
37TH ST
>
1318
>
1318 37TH ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2021 11:06:08 AM
Creation date
3/31/2017 9:47:55 AM
Metadata
Fields
Template:
Address Document
Street Name
37TH ST
Street Number
1318
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
797
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V <br />Plan Check Review Nos. B59674, B59674, B59676 <br />October 13, 1998 <br />Page 6 of 9 <br />Accessibility <br />The site plan should show an accessible route of travel from the public way to the accessible <br />entrances of each building. Section 1103.2.2 <br />/l. Curbs, guardrails, or raised truncated domes should be provided where the accessible route of <br />/ travel crosses or adjoins vehicular areas. Sections 1106.4.8 & 1106.17 <br />3The exterior accessible parking spaces should be shown with access isles, curb cuts and be located <br />as nezr as possible to the accessible entrances. Section 1107 <br />Each required accessible parking space not designated for accessible dwelling units should be <br />shown as having a sign 3'-5' high centered at the head of the space and bearing the words, "State <br />Disabled Parking Permit Required." Sections 1106.27.2.4 & 1107.3 <br />�S The accessible parking spaces should be shown with a maximum 1:48 slope. Section 1107.2.4 <br />Stairway treads should be shown to have rounded, non -slip nosings. Section 1106.9.3 <br />07. reas of evacuation assistance and all their details such as size, location, telephone, fire <br />rotection, signs, etc. should be shown. 48" clear width between handrails in each stairway per <br />Section 1104.1. Note that this office should be contacted prior to resubmission if the Exception is <br />chosen for compliance. <br />All doors in the building on the accessible route of travel with a latch set or lock set should be <br />shown as having lever -type operating hardware. Section 1106.3.1 <br />y Signs for the visually impaired should be provided to identify accessible entrances, public toilet <br />rooms, stairs, and elevators. Where other signs are provided, they should also comply. Sections <br />1103.2.4 & 1106.16 <br />Dwelling Units <br />Per a conversation with the architect on 10/9/98, all dwelling units are designed to be adaptable. <br />The plans should show which units will be the adaptable Type A units (5 units total required on <br />site), all other units onsite will be assumed to be adaptable Type B units per Section 1103.1.8.2 & <br />1106.27. <br />
The URL can be used to link to this page
Your browser does not support the video tag.