Laserfiche WebLink
��� <br /> + <br /> d. Prior to issuance of any perniits, Iandscaping plans must be reviewed and approved Ly I <br /> the Planning Depattment per Section 35.100 of the Zuning Code. 7'he landscaping <br /> plan must show location and dimensio�s of required vegetated swales, wetponds, <br /> detention ponds, rockeries and retaining walls, and grading at 2 foot intervals. <br /> Irrig:�tion systems mus[ be provided in all landscaped areas per Section 35.130 of the <br /> Zoning Code. A 2 year maintenance assurance device must be provided for the <br /> landscaping per Section 35.1308 of th,: Zoning Code. <br /> 19. Fire flow requirements for this strucmre are 1,750 GPM. <br /> 20. A fire hydrant is requ(red within 200 driving feet, but not closer than 50 feet, of every <br /> strucmre. The location of the hydrants shown on the site '�n are acceptable. <br /> 21• Fir oreceion (S rinkl r yctenil - An approved automatic suppression system shal( bc <br /> previded as required by City Ordinance No. 1902-92, Chap[er 16.76 of the [verett Municipal <br /> Code. <br /> Plans for any such system mus[ be submitted to the Building Depar[ment and the Everett Fire <br /> Department for examination and approval. Such plans must include plans for the underground <br /> mains that will supply the sprinkler system. <br /> Above ground sprinkler piping must be hydrosta[ically tested as established in NFPA Standard <br /> 13. Underground piping must be hydrostatically tested and flushed as established in NFPA <br /> Standard 24 tbr Frivate fire mains. All such tests must be witnessed by a Fire Department <br /> inspector. Call 259-8123 to make an appointment for inspection. <br /> Contracrors' materiTls and test ccrti�cates must be submitted [o the Everett Pire Department <br /> prior [o issuance of an;� Certificates of Occupancy. <br /> Call 257-8123 for more inforntatior.. <br /> ��� Eii�Alarm y�•tem - An approved automatic fire de[ection system shall be provided as reyuired <br /> hy City Ordinance No. 1902-92, Chapte: 16.76 of the Evem[t Municipal Code. <br /> Plans for such system shall be submitted to the Fire Marshal for review and approval prior ro <br /> installa[ion. Submittal shall include cut sheets of all equipm�nt intendcd for use. Apprepnate <br /> trip tests, witnessed by a Fire Department inspector, shall be performed, along with a <br /> certificate of campletion, prior ro final acceptance of the system. <br /> Fire alarni systems shall be installed according ro NPPA Standard 72. <br /> Fire alarm systems shall be instai!ed under permit of the City of Gverett Building Uepartmeer. <br /> Electrical inspections and approval are reyuircd prior to calling tbt acceptance tests. Call 257- <br /> R810 for permit information. <br /> 23. Portable Fire Protection - A portable fire extinguisher with a minimum UL rating of 2A:10- <br /> B:C must be previded within 75 feet travel distance on all Floors of each huilding during I <br /> construction and prior ro occupancy. <br /> '4. Fire lanes must be provided as required in Gverett Municipal Code 46.44. Fire lanes must be <br /> idendtied by red curbs with white stenciling stating "NO PARKING - FIRE LANG" and <br /> vertical signs stating "NO PARKING - PIRE LANE- - TOW AWAY ZONE." Location nwst <br /> he approvcd by thc Pirc Mnrshal. <br /> i <br /> e <br />._..� _ _ <br />