My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1508 49TH ST SW 2018-01-02 MF Import
>
Address Records
>
49TH ST SW
>
1508
>
1508 49TH ST SW 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 10:26:19 AM
Creation date
3/31/2017 2:56:54 PM
Metadata
Fields
Template:
Address Document
Street Name
49TH ST SW
Street Number
1508
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The project as proposed does not comply with minimum Land Division design <br />standards, design and construction standards. To receive preliminary approval <br />from the City, the Cluster Subdivision must be modified to comply with land <br />division design standards. Based upon the information contained in the <br />application, it appears a reduction in the number of proposed lots will be required <br />to comply with applicable standards and regulations. <br />2. Street Standards: The proposed street right-of-way/street width is less than the <br />City minimum standards (EMC 18.28.100 A). A Local Access 'A"street is <br />required to have a 50 feet of right-of-way, 28 feet of pavement width curb -to -curb, <br />sidewalks on both sides, and 4 off-street parking stalls per dwelling unit per City <br />standards 300. The street width proposed meets this standard but the right-of- <br />way is unacceptable. A 10-Foot utility easement is required behind the 50 right- <br />of-way for other public utilities such as PUD, Verizon and others. This public <br />utility easement area behind the right-of-way may be used for landscaping and <br />street trees. The City Engineer in some cases will allow a 20-foot setback from <br />the back of the 5-foot sidewalks to the face of the garage for the parking of the <br />required 4 off street vehicles. This would be 14 to 16 foot setback from the 50- <br />foot right-of-way. The City has approved a 28-foot street within a 46 to 48 foot <br />right-of-way if the applicant can dimeistate that all facilities can be <br />accommodated included curb cuts, driveway widths, and parking pads. The City <br />Engineer has the authority to deviate from this construction and street <br />classification standard but in this case has chosen not to since the project is <br />designed below other minimum standards. Some of the minimum standards that <br />are not being meet are. The curb cut is less than 20 feet along with a driveway <br />of about 16 feet wide and some of the garages are 20 to 25 feet from the 40-foot <br />right-of-way. The shared driveways parking pad have fhe same problem except <br />they extend into the common driveway. The cul-do-:.-ac has no vertical curb and <br />fails to meet ADA standards; in most cases the parking stalls cross lot lines or <br />conflict with access and provides no protection for landscaping areas proposed. <br />The cul-de-sac is the smallest allowed by City standards and has 9 out of 11 lots <br />using it for access. <br />3. Proposed Lots: Based on the need to increase the required right-of-way width to <br />meet minimum City standards, the entire plat and lot layout must be redesigned. <br />Therefore, the deficiencies for each lot listed hereir, are intended to provide the <br />applicant with the information needed to redesign the plat with a layout that <br />meets the Citys minimum standards. While the cluster alternative for subdividing <br />provides additional flexibility above conventional subdivision standards, there are <br />minimum functional considerations that must be incorporated into the plat design. <br />The following list identifies project design deficiencies that must be addressed in <br />the re -design of the plat to either meet rrrnimum City standards, or to provide a <br />functional plat layout: <br />I <br />2930 Wetmore, Suite #8A, Everett, WA 98201-4044 V (425) 257-8731, Fax (425) 257-8742 ' t .— <br />
The URL can be used to link to this page
Your browser does not support the video tag.