My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2400 33RD ST 2018-01-02 MF Import
>
Address Records
>
33RD ST
>
2400
>
2400 33RD ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2022 11:55:02 AM
Creation date
4/1/2017 3:28:41 PM
Metadata
Fields
Template:
Address Document
Street Name
33RD ST
Street Number
2400
Notes
FOR EVERETT STATION SEE 3201 SMITH ST
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
844
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 01400 <br />QUALITY CONTROL <br />structure will be more than superficially wet under service <br />conditions, the cores shall be tested after moisture conditioning in <br />accordance with ASTM C42. <br />d. Concrete in the area represented by the core testing will be <br />considered adequate if the average strength of the cores is equal <br />to at least 85 percent of the specified strength requirement and if <br />no single core is less than 75 percent of the specified requirement. <br />e. Repair core holes in the concrete found acceptable with an <br />approved dry -pack or non -shrinking mortar. <br />f. If the core tests are inconclusive or are impractical to obtain, or if <br />structural analysis does not confirm the safety of the structure, <br />load tests may be directed by the Resident Engineer in <br />accordance with ACI 318. <br />g. Concrete work evaluated by structural analysis or by results of a <br />load test and found deficient shall be corrected in a manner <br />satisfactory to the Resident Engineer. <br />h. All investigations, testing. Load tests, and correction of <br />deficiencies shall be performed and approved by the Resident Engineer, <br />at the expense of the Contractor. <br />G. Masonry <br />1. General: The testing agency shall check reinforcing steel placement prior to <br />Grouting; quality of block placement and appearance; mortar work; and shall monitor <br />all grouting operations in accordance with the Building Code. <br />2. The inspection -testing agency shall make field tests of mortar and grout in <br />accordance with the Building Code. Grout shall be tested for each 20 cubic yards <br />placed each day. For mortar one test shall be conducted for every 750 square feet <br />of construction. <br />3. Provide prism tests in accordance with the Building Code. <br />H. Structural Steel — General <br />1. Mill Certificates: Mill certificates or affidavits and manufacturer's certification <br />shall be supplied to the inspector for verification of steel materials. Testing <br />laboratory shall be notified at lest three weeks in advance of fabrication and <br />supplied with the reports so that shop inspection may be performed. <br />2. General Inspection: <br />a. Testing agency shall be at the fabricator's plant to verify that materials <br />used match the mill tests or affidavits of test reports; that fabrication, <br />welding procedures, surface preparation, and shop painting meet <br />specifications; and that the work in progress conforms with project <br />requirements. <br />b. Testing agency shall visually check fabricated steel delivered to the job to <br />confirm that the work is in compliance with the approved shop drawings <br />and shall make any physical tests, measurements, etc., believed to be <br />necessary. <br />C. Testing agency shall witness and report all corrections performed by the <br />steel fabricator occurring on the fabricator's own initiative. <br />d. Testing agency shall be present during steel erection at all times. <br />Capital Projects Commuter Rail 01400-6 IFB No. RTA/CP 21-06 <br />Everett Station Phase 2 QUALITY CONTROL <br />
The URL can be used to link to this page
Your browser does not support the video tag.