My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2400 33RD ST CONTRACT AGREEMENT 2016-01-01 MF Import
>
Address Records
>
33RD ST
>
2400
>
CONTRACT AGREEMENT
>
2400 33RD ST CONTRACT AGREEMENT 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2017 3:28:48 PM
Creation date
4/1/2017 3:32:27 PM
Metadata
Fields
Template:
Address Document
Street Name
33RD ST
Street Number
2400
Tenant Name
CONTRACT AGREEMENT
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
382
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTACHMENT A TO SECTION 01900 <br />REVISIONS TO THE STANDARD PLANS AND SRECIFICATIONS <br />Filter Fabric <br />Underdrain pipe and gravel backiill for drains shall be wrapped with a non-woven, needle-punch <br />geotextile tor underground drainage, moderate survivability, Class B in accordance with Section 9- <br />33.2, Geotextile Properties Tables 1 and 2. <br />Cleanouts <br />Cleanouts shall be in accordance with the Special Provision Sewe� Cleanouts. <br />Gravel Backiill for Drains <br />Gravel back(ill tor drains shall be in accordance with Section 9-03.12(4). <br />Trench Drain <br />The irench draln stiall be a 6-inch wide system with 0.75% slope as manufactured by Zurn Industies, <br />Inc., model Perma-trench Z-886 with ADA compatible ductile iron grate model Z-886-HPD, and exira <br />heavy-duty frame asscmbiy with anchor studs and grate lockdown hardware, or equal approved by <br />the Resident Engineer. Discharge will be by bottom outlet to a drain system with cleanouts as <br />shown in ihe Plans. <br />Floor Drain <br />Area Drains: ANSI A112.21.2 with round nickel-bronze strainer and accessories: Membrane flange <br />and membrane clamp with integrai grave stop, with adjustable under deck clamp and roof sump <br />receiver (where indicated), weterproofing flange. <br />a. Area Drain (Outdoor): Cast iron body, with cast iron bar grate. sediment bucket, and flashing <br />collar. <br />Construction Requirements <br />Underdrain and trench drain shali be installed to ihe lengihs and inverts as indicated in the Plans and in <br />the detail. <br />STORM SEWERS <br />Materials <br />Section 7-04.2 is supplemented with the following: <br />Pipe <br />Pipe materiais shall comply with the requirements of City of Everett Design and Construction <br />Standards and Specifications. Unless otherwise specified on ihe drawing, all storm sewer pipe shall <br />be regular rubber gasketed concrete, polyethylene, or PVC pipe. Steel or aluminum pipe shall not <br />be used. <br />Rubber Gasketed Joints <br />Flexible joinis shall be rubber-gasketed in accordance with the Standard Speci(ications. Mortared, <br />dry-packed, or cast-in-place joints will be permitted only for connection to or through manholes and <br />catch basins. A fiexible gasketed joint shall be instalied within 1 foot of each connection to or <br />through said manholes and catch basins. Connections to catch bas��s and inlets with ductile iron or <br />concrete pipe shall be cemant mor�ared. <br />The (ollowing producers of polyethylene and PVC pipe have been preyualified in accordance with <br />the requirements ot Section 9�05: <br />Type of Pipe Watertight Joints Approved <br />for Diameters Thru: <br />AASHTO M 294 Type S Polyethylene Storm Sewer Pipe: <br />ADS N-12 Advanced Drainage Systems, Inc. 24" <br />Capital Projects Commuter Rail Attachment A to Section 01900 - 16 IFB No. RTAlCP 21-06 <br />� Everett Station Phase 2REVISIONS TO THE STANDARD PLANS AND SPECIFICATIUNSAddendum No.4 <br />�o <br />
The URL can be used to link to this page
Your browser does not support the video tag.